Navien · Tankless water heater
E438 Circulation pump abnormal (with air handler)
What the control is telling you
The circulation pump is not working properly when an air handler (AHU/H2Air) is installed.
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
Likely causes
- Pump not running or seized
- External pump not wired to TB1
- Pump draws more than the PCB output allows
Test and repair steps
- Check that the circulation pump runs (manual's listed action).
- Run Service menu > 3. Test Mode > 4. Pump (A2) or Ext.Pump (S2): the pump runs 10 s / stops 5 s, 5 times.
- External pump wired to TB1 on the PCB with the external pump wire; max 150 W, 1.5 A - use a relay for a bigger pump.
- Check the space heating loop for closed valves or air.
- Reset once with the Back button on the front panel and note whether the code returns.
- Code back after a reset? Stay at the unit and phone Navien Technical Support, 1-800-519-8794.
Settings for these units
- Installation clearances (indoor / outdoor) · Navien NPE-2
- Water quality limits and flushing schedule · Navien NPE-2
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.2 Understanding Error Codes, p.17. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.