Midea · Heat pump
PH90 Evaporator high temperature protection
What the control is telling you
The indoor coil temperature is too high (normally in heating), so the unit protects itself.
Applies to: DLCURAH18-60 AAK/ABK single-zone heat pump outdoor units (18K-60K, regular and High Heat)
Likely causes
- Low indoor airflow in heating - dirty filter, blower problem, closed registers
- Overcharge
- Indoor coil sensor fault
Test and repair steps
- Check/replace the indoor filter.
- Check indoor blower operation and ductwork/registers.
- Check refrigerant charge.
- Check the indoor coil temperature sensor.
Settings for these units
Outdoor unit minimum clearances · Midea DLCURA ducted single-zone inverter heat pump (outdoor)
| Side | Minimum |
|---|---|
| A - top | 24 in. (610 mm) |
| B - right side (service side) | 24 in. (610 mm) |
| C - front (air outlet) | 24 in. (610 mm) |
| D - left side | 4 in. (101 mm) |
| E - rear (air inlet) | 4 in. (101 mm) |
| Above max snow depth | 2 in. (50 mm) |
Side letters taken from Fig. 8 drawing.
Units facing each other: 59 in. (150 cm) or more; do not blow into another unit's inlet.
Models that show this code
12 models in Midea DLCURA ducted single-zone inverter heat pump (outdoor)
Other codes on the same units
- PC43 Compressor lack-phase protection
- PC44 Outdoor unit zero-speed protection
- PC45 Outdoor IR chip drive failure
- PC46 Compressor speed out of control
- PC49 Compressor over-current failure
- PH91 Evaporator low temperature protection
- DF DF shown on outdoor display - normal, not a malfunction
- FC FC shown on outdoor display - normal, not a malfunction
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Midea/Carrier DLCURA Installation Instructions (Catalog DLCURA-03SI), Table 11 Outdoor Unit Diagnostic Codes, p.19. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.