Midea · Heat pump
DF DF shown on outdoor display - normal, not a malfunction
What the display is showing
The outdoor unit diagnostic table notes that seeing DF is normal and is not a malfunction. The installation manual does not spell out the abbreviation; refer to the Midea service manual for the exact meaning.
Applies to: Midea DLCURA ducted single-zone inverter heat pump (outdoor)
Settings for these units
Outdoor unit minimum clearances · Midea DLCURA ducted single-zone inverter heat pump (outdoor)
| Side | Minimum |
|---|---|
| A - top | 24 in. (610 mm) |
| B - right side (service side) | 24 in. (610 mm) |
| C - front (air outlet) | 24 in. (610 mm) |
| D - left side | 4 in. (101 mm) |
| E - rear (air inlet) | 4 in. (101 mm) |
| Above max snow depth | 2 in. (50 mm) |
Side letters taken from Fig. 8 drawing.
Units facing each other: 59 in. (150 cm) or more; do not blow into another unit's inlet.
Models that show this code
12 models in Midea DLCURA ducted single-zone inverter heat pump (outdoor)
Other codes on the same units
- PC43 Compressor lack-phase protection
- PC44 Outdoor unit zero-speed protection
- PC45 Outdoor IR chip drive failure
- PC46 Compressor speed out of control
- PC49 Compressor over-current failure
- PH90 Evaporator high temperature protection
- PH91 Evaporator low temperature protection
- FC FC shown on outdoor display - normal, not a malfunction
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Midea DLCURA Installation Instructions DLCURA-03SI, Table 11 Outdoor Unit Diagnostic Codes note, p.21. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.