Gree · Heat pump
Outdoor comm light blinking Outdoor communication light blinking (normal)
What the display is showing
At power-up the outdoor communication light blinks as a normal sign that data is flowing; after each good group of signals the blinking pauses for about 0.2 to 0.3 s. A light that stays on permanently means there is no communication, and a light that is on 1 s and off 1 s means another outdoor unit has a fault.
Applies to: Vireo GEN3 9-24k (3VIR..HP115/230V1A)
Models that show this code
6 models in Gree Vireo GEN3
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 6. Function and Control, outdoor units. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.