Daikin · Air conditioner
E36 Abnormal start-up
What the control is telling you
Thermostat shows 36, outdoor board display shows E36. Something went wrong while the compressor was starting.
Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)
Likely causes
- Dirty or blocked outdoor coil, or a restriction in the lines
- Lost phase on the compressor wires
- Uneven compressor load
- Bad control board
Test and repair steps
- Kill power at the disconnect before opening the control box or touching wiring.
- Clean the outdoor coil and check the lines.
- Check the compressor wires between the board and the compressor.
- Replace the control board if the code keeps coming back.
Models that show this code
10 models in Daikin FIT DC6VS/DC9VSA
Other codes on the same units
- E30 Control board may need replacing
- E32 Outdoor control board overheating (critical)
- E34 High current detected
- E35 High current, possible short circuit
- E37 Control board may need replacing (fan motor link)
- E38 Compressor voltage problem
- E39 Control board may need replacing (thermistor input)
- E40 Compressor setup does not match the unit
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.