Daikin · Air conditioner
E35 High current, possible short circuit
What the control is telling you
Thermostat shows 35, outdoor board display shows E35. The control board saw high current that points to a possible short.
Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)
Likely causes
- Short circuit
- Stop valve not fully open
- Too much refrigerant
- Bad control board
- Bad compressor
Test and repair steps
- Kill power at the disconnect before opening the control box or touching wiring.
- Check the clearances around the outdoor unit.
- Open both stop valves all the way.
- Check the charge.
- Check the compressor.
- Replace the control board if everything else is good.
Models that show this code
10 models in Daikin FIT DC6VS/DC9VSA
Other codes on the same units
- E29 Liquid temperature sensor out of range
- E30 Control board may need replacing
- E32 Outdoor control board overheating (critical)
- E34 High current detected
- E36 Abnormal start-up
- E37 Control board may need replacing (fan motor link)
- E38 Compressor voltage problem
- E39 Control board may need replacing (thermistor input)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.