Daikin · Air conditioner
57 Sweating on the board cooling loop
What the control is telling you
The thermostat shows 57; the board shows nothing. The control senses condensation on the refrigerant cooling loop of the board (3.5-5.0 ton FIT and 3.0-4.0 ton Enhanced Capacity/High Efficiency FIT only).
Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)
Likely causes
- Refrigerant leak
- Low charge
- Bad indoor EEV or its coil
- Thermistor bad or not plugged in right
Test and repair steps
- Refrigerant work only by a certified tech. This unit runs on an A2L refrigerant: no open flame near a leak.
- Leak test the system.
- Check the charge and adjust.
- Check the indoor EEV and its coil.
- Check the thermistor plugs.
Models that show this code
10 models in Daikin FIT DC6VS/DC9VSA
Other codes on the same units
- 52 Repeated compressor faults (minor)
- 53 Repeated outdoor fan / board faults (minor)
- 54 Repeated low discharge superheat faults (minor)
- 55 Repeated high discharge temperature faults (minor)
- E11 System start-up test not done
- E12 Control board memory error
- E13 Repeated high pressure faults (critical)
- E15 Repeated low pressure faults (critical)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.45 (printed page). Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.