Carrier · Furnace
t° Menu: supply and return air temperature display
What the display is showing
Main menu item (59MN7C) that turns on the display of supply and return air temperature in F or C. Default is off. When on, the display rotates through the operating mode, supply air temperature (SAT), return air temperature (RAT) and the difference between them. This only happens while heating, cooling or heat pump operation is running.
Applies to: 59MN7C modulating furnace
What to do
- Scroll to t° and choose F or C (or off).
- If the displayed SAT does not agree with a thermometer, move the SAT sensor further from the furnace or past a bend in the duct.
Settings for these units
- Filter sizes by casing width and filter cabinet · 59SC6A
- Filter sizes by casing width and filter cabinet · 59TP6A
- Minimum clearances to combustibles · 59TP6A
- Minimum clearances to combustibles · 59SC6A
- Filter sizes by casing width · 58SB0A/58SB1A
- Filter sizes by casing width · Payne PG96VTA
Models that show this code
6 models in 59MN7C
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier 59MN7C installation instructions, Temperature Display, Table 18, p.47. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.