C1 Flue blockage at start-up
What the control is telling you
Heavy blockage was seen at start-up because of too little combustion air; the unit shuts down for safety.
Applies to: Bosch Greentherm T9800 SE 160/199 and T9900 SE 160/199 / i 199 tankless water heaters
Likely causes
- Blocked intake or exhaust
- Vent too long
- Dirty air filter
Test and repair steps
- Hold the power button down roughly 3 s to clear the stored error.
- Look for anything restricting the combustion air inlet or the exhaust pipes and their terminals.
- Confirm the vent length is within specification.
- Clean or replace the air filter.
- Run the gas and air tuning procedure.
- The water supply can also be shut off and reopened to reset (limited to 3 times per hour); allow up to 3 minutes for start-up.
Models that show this code
6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE
Other codes on the same units
Sequence of operation
What the unit does around this code, step by step.
- Flow-activated hot water call · Domestic hot water
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greentherm T9800 SE 160/199 installation 6720816815 (06.2023), Table 24 Error code diagnostics, p.65-69; Bosch Greentherm T9900 SE 160/199 | i 199 installation 6 720 813 635 (2024-06), section 9.1 Error code diagnostics, p.68-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.