Weil-McLain · Boiler · EG / PEG Series 7 series

EG 30-75 parts

19 replacement parts that fit the Weil-McLain EG 30-75, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Draft hood
Part number varies by model
450-021-292 (EG 30-35); 450-021-258 (EG 40-45); 450-021-293 (EG 50-55); 450-021-261 (EG-65); 450-021-262 (EG-75)1
Collector hood
Part number varies by model
450-014-733 (EG-30, 35); 450-014-734 (EG-40, 45); 450-014-735 (EG-50, 55); 450-014-736 (EG-65); 450-014-737 (EG-75)1
Manifold
Part number varies by model
591-125-533 (EG-30); 591-125-538 (EG-35); 591-125-534 (EG-40); 591-125-539 (EG-45); 591-125-535 (EG-50); 591-125-540 (EG-55); 591-125-541 (EG-65); 591-125-542 (EG-75)1
Section assembly complete without heater opening
Not shown in illustrations
321-811-095 (EG 30-35); 321-811-115 (EG 40-45); 321-811-125 (EG-50-55); 321-811-135 (EG-65); 321-811-145 (EG-75)1
Front base panel
Part number varies by model
451-800-000 (EG-30, 35); 451-800-001 (EG-40, 45); 451-800-002 (EG-50, 55); 451-800-003 (EG-65); 451-800-004 (EG-75)1
Base front access panel with flame rollout switch bracket
Part number varies by model
451-800-040 (EG-30, 35); 451-800-041 (EG-40, 45); 451-800-039 (EG-50); 451-800-042 (EG-55); 451-800-043 (EG-65); 451-800-044 (EG-75)1
Back burner support
Part number varies by model. Manual prints EG-34 (likely EG-35)
451-800-085 (EG-30); 451-800-086 (EG-34); 451-800-087 (EG-40); 451-800-088 (EG-45); 451-800-089 (EG-50); 451-800-090 (EG-55); 451-800-092 (EG-65); 451-800-094 (EG-75)1
Back base panel
Part number varies by model
451-800-010 (EG-30, 35); 451-800-011 (EG-40, 45); 451-800-012 (EG-50, 55); 451-800-013 (EG-65); 451-800-014 (EG-75)1
Back base channel
Part number varies by model
451-800-020 (EG-30, 35); 451-800-021 (EG-40, 45); 451-800-022 (EG-50, 55); 451-800-023 (EG-65); 451-800-024 (EG-75)1
Damper actuator510-512-3371
Wire harness - damper
Part number varies by boiler type
381-359-436 (EG water); 591-391-795 (EG steam)1
Pilot burner assembly
Common to steam and water
511-330-2181
Pilot tubing with fittings, 1/8 in x 22-3/4 in560-742-86011/8 in x 22-3/4 in
Rollout thermal fuse512-050-2301228 °C
Control module, natural gas (water boilers, no tankless heater)
Water boiler without tankless heater
383-301-2111
Terminal block, thermostat wiring381-359-4301
Wire harness EG-30 thru 75, PEG-30 thru 65 steam, probe LWCO540-130-9621
High altitude conversion kit, 2,000 to 6,999 ft510-811-99612,000 to 6,999 ft
High altitude conversion kit, 7,000 to 10,000 ft510-811-99717,000 to 10,000 ft

Source: EG/PEG Series 7 boiler manual, p. 84 (pages 84, 85, 86). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.