Weil-McLain · Boiler parts
Weil-McLain EG / PEG Series 7: parts list
77 replacement parts with OEM part numbers for 23 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Gas valve Manufacturer listed as Resideo; the manual gives only this designation | VR8204/VR8304 | EG / PEG Series 7 | 1 | |
| Left hand end section with heater opening (Pattern 1814) | 311-800-014 | All EG/PEG 30-75 | 1 | |
| Left hand end section without heater opening (Pattern 1813) | 311-800-007 | All EG/PEG 30-75 | 1 | |
| Right hand end section without heater opening (Pattern 18128) | 311-800-029 | All EG/PEG 30-75 | 1 | |
| Intermediate section (Pattern 1815) | 311-800-010 | All EG/PEG 30-75 | 1 | |
| Draft hood Part number varies by model | 450-021-292 (EG 30-35); 450-021-258 (EG 40-45); 450-021-293 (EG 50-55); 450-021-261 (EG-65); 450-021-262 (EG-75) | EG 30-75 | 1 | |
| Collector hood Part number varies by model | 450-014-733 (EG-30, 35); 450-014-734 (EG-40, 45); 450-014-735 (EG-50, 55); 450-014-736 (EG-65); 450-014-737 (EG-75) | EG 30-75 | 1 | |
| Burner, stainless tube, regular | 512-200-000 | All EG/PEG 30-75 | 1 | |
| Burner, stainless tube, with pilot bracket | 512-200-001 | All EG/PEG 30-75 | 1 | |
| Manifold Part number varies by model | 591-125-533 (EG-30); 591-125-538 (EG-35); 591-125-534 (EG-40); 591-125-539 (EG-45); 591-125-535 (EG-50); 591-125-540 (EG-55); 591-125-541 (EG-65); 591-125-542 (EG-75) | EG 30-75 | 1 | |
| Main burner orifice, natural gas, 2.35 mm | 560-529-991 | EG 30-65 | Order enough to replace all orifices in a base | 2.35 mm, natural gas |
| Main burner orifice, natural gas, 2.30 mm | 560-528-975 | EG-75 | Order enough to replace all orifices in a base | 2.30 mm, natural gas |
| Section assembly complete without heater opening Not shown in illustrations | 321-811-095 (EG 30-35); 321-811-115 (EG 40-45); 321-811-125 (EG-50-55); 321-811-135 (EG-65); 321-811-145 (EG-75) | EG 30-75 | 1 | |
| Section assembly complete with heater opening Not shown in illustrations | 321-811-100 (EG-35); 321-811-110 (EG 40-45); 321-811-120 (EG 50-55); 321-811-130 (EG-65); 321-811-140 (EG-75) | EG 35-75 | 1 | |
| Retort cement (1 quart) Not shown in illustrations | 591-602-913 | All EG/PEG 30-75 | 1 quart | 1 quart |
| Flue brush Not shown in illustrations | 591-706-214 | All EG/PEG 30-75 | 1 | |
| Front base panel Part number varies by model | 451-800-000 (EG-30, 35); 451-800-001 (EG-40, 45); 451-800-002 (EG-50, 55); 451-800-003 (EG-65); 451-800-004 (EG-75) | EG 30-75 | 1 | |
| Base insulation kit (front and rear base panel insulation, water glass, boiler cement) | 510-811-660 | All EG/PEG 30-75 | 1 | |
| Base front access panel with flame rollout switch bracket Part number varies by model | 451-800-040 (EG-30, 35); 451-800-041 (EG-40, 45); 451-800-039 (EG-50); 451-800-042 (EG-55); 451-800-043 (EG-65); 451-800-044 (EG-75) | EG 30-75 | 1 | |
| Back burner support Part number varies by model. Manual prints EG-34 (likely EG-35) | 451-800-085 (EG-30); 451-800-086 (EG-34); 451-800-087 (EG-40); 451-800-088 (EG-45); 451-800-089 (EG-50); 451-800-090 (EG-55); 451-800-092 (EG-65); 451-800-094 (EG-75) | EG 30-75 | 1 | |
| Back base panel Part number varies by model | 451-800-010 (EG-30, 35); 451-800-011 (EG-40, 45); 451-800-012 (EG-50, 55); 451-800-013 (EG-65); 451-800-014 (EG-75) | EG 30-75 | 1 | |
| Back base channel Part number varies by model | 451-800-020 (EG-30, 35); 451-800-021 (EG-40, 45); 451-800-022 (EG-50, 55); 451-800-023 (EG-65); 451-800-024 (EG-75) | EG 30-75 | 1 | |
| Base side rail | 451-800-070 | All EG/PEG 30-75 | 2 required | |
| Spill switch | 510-300-013 | All EG/PEG 30-75 | 1 | |
| Cover plate for heater opening (rectangular) | 389-900-103 | All EG/PEG 30-75 | 1 | Rectangular |
| Gasket for cover plate (rectangular) | 590-317-579 | All EG/PEG 30-75 | 1 | Rectangular |
| Cover plate for heater opening (round) | 389-900-101 | All EG/PEG 30-75 | 1 | Round |
| Gasket for cover plate (round) | 590-317-495 | All EG/PEG 30-75 | 1 | Round |
| Flue baffle | 460-003-790 | All EG/PEG 30-75 | 1 per joint | |
| Section replacement kit (3 in and 6 in elastomer seal, 2 pieces rope, tube of silicone) Not shown in illustrations | 381-800-667 | All EG/PEG 30-75 | 1 per joint between sections | |
| 3 in diameter bottom elastomer seal | 592-800-010 | All EG/PEG 30-75 | 1 per joint | 3 in diameter |
| 6 in diameter top elastomer seal | 592-800-007 | All EG/PEG 30-75 | 1 per joint | 6 in diameter |
| Sealer for sections (2 pieces rope, tube of silicone per joint) Not shown in illustrations | 591-641-865 | All EG/PEG 30-75 | Per joint between sections | |
| 1/2 in x 14 in tie rod, without nut Not shown in illustrations | 560-234-470 | EG-30, 35 | 2 per boiler | 1/2 in x 14 in |
| 1/2 in x 18-1/2 in tie rod, without nut Not shown in illustrations | 560-234-475 | EG-40, 45 | 2 per boiler | 1/2 in x 18-1/2 in |
| 1/2 in x 22-3/4 in tie rod, without nut Not shown in illustrations | 560-234-480 | EG-50, 55 | 2 per boiler | 1/2 in x 22-3/4 in |
| 1/2 in x 27 in tie rod, without nut Not shown in illustrations | 560-234-485 | EG-65 | 2 per boiler | 1/2 in x 27 in |
| 1/2 in x 31-1/4 in tie rod, without nut Not shown in illustrations | 560-234-490 | EG-75 | 2 per boiler | 1/2 in x 31-1/4 in |
| 1/2 in nut Not shown in illustrations | 561-928-221 | All EG/PEG 30-75 | 2 per tie rod | 1/2 in |
| 1/2 in lock washer Not shown in illustrations | 562-248-668 | All EG/PEG 30-75 | 1 per tie rod | 1/2 in |
| Vent damper assembly 5 in Approved dampers only | 381-800-864 (water boiler); 381-800-475 (steam boiler) | EG-30, EG-35 | 1 | 5 in |
| Vent damper assembly 6 in Approved dampers only | 381-800-865 (water boiler); 381-800-476 (steam boiler) | EG-40, EG-45 | 1 | 6 in |
| Vent damper assembly 7 in Approved dampers only | 381-800-866 (water boiler); 381-800-477 (steam boiler) | EG-50, EG-55 | 1 | 7 in |
| Vent damper assembly 8 in Approved dampers only | 381-800-869 (water boiler); 381-800-478 (steam boiler) | EG-65, EG-75 | 1 | 8 in |
| Damper actuator | 510-512-337 | EG 30-75 | 1 | |
| Wire harness - damper Part number varies by boiler type | 381-359-436 (EG water); 591-391-795 (EG steam) | EG 30-75 | 1 | |
| Pilot burner assembly Common to steam and water | 511-330-218 | EG 30-75 | 1 | |
| Gas valve, natural gas 1/2 in x 1/2 in Natural gas | 511-044-381 | EG 30-50 | 1 | 1/2 in x 1/2 in |
| Gas valve, natural gas 3/4 in x 3/4 in Natural gas | 511-044-382 | EG 55-75 | 1 | 3/4 in x 3/4 in |
| Pilot tubing with fittings, 1/8 in x 22-3/4 in | 560-742-860 | EG 30-75 | 1 | 1/8 in x 22-3/4 in |
| Rollout thermal fuse | 512-050-230 | EG 30-75 | 1 | 228 °C |
| Control module, natural gas (water boilers, no tankless heater) Water boiler without tankless heater | 383-301-211 | EG 30-75 | 1 | |
| Supply temperature sensor LWCO | 381-356-589 | EG 30-75 water | 1 | |
| Wire harness - sensor, water | 591-392-106 | EG 30-75 water | 1 | |
| Wire harness - power J-box to module | 381-359-447 | EG 30-75 water | 1 | |
| Wire harness - circulator (with molex) | 381-356-528 | EG 30-75 water | 1 | |
| Wire harness, water without tankless heater Without tankless heater | 381-800-893 | EG 30-75 water | 1 | |
| Control transformer 24VAC 50 VA Water without tankless heater | 383-500-628 | EG 30-75 water | 1 | 24VAC 50 VA |
| Terminal block, thermostat wiring | 381-359-430 | EG 30-75 | 1 | |
| UCS ignition control, natural gas (steam) Steam boilers only | 511-330-097 | EG 30-75 steam | 1 | |
| Control limit with 1/2 in NPT well Steam boilers only | 510-312-250 | EG 30-75 steam | 1 | 1/2 in NPT well |
| Float type LWCO Steam boilers only | 511-114-494 | EG 30-75 steam | 1 | |
| Wire harness EG-30 thru 75 steam, float LWCO | 540-130-961 | EG 30-75 steam | 1 | |
| Probe type LWCO Steam boilers only | 510-811-403 | EG 30-75 steam | 1 | |
| Wire harness EG-30 thru 75, PEG-30 thru 65 steam, probe LWCO | 540-130-962 | EG 30-75, PEG 30-65 steam | 1 | |
| Wire harness - thermostat | 591-391-994 | EG 30-75 steam | 1 | |
| Transformer, relay 120/24VAC 40 VA | 510-312-166 | EG 30-75 steam | 1 | 120/24VAC 40 VA |
| Control module, natural gas (water with tankless heater) Water boiler with tankless heater | 383-301-211 | EG 30-75 water | 1 | |
| Wire harness EG-35 thru 75 water with tankless heater With tankless heater | 381-800-884 | EG-35 to EG-75 water | 1 | |
| Outdoor temperature sensor, wired Optional | 381-356-586 | Optional kit | 1 | |
| Outdoor temperature sensor, wireless Optional | 384-000-325 | Optional kit | 1 | |
| Antifreeze, Sentinel X500, 1 gallon | 592-900-029 | Optional kit | 1 gallon | 1 gallon |
| Antifreeze, Sentinel X500, 5 gallon | 592-900-006 | Optional kit | 5 gallon | 5 gallon |
| Corrosion inhibitor, Sentinel X100 | 592-900-002 | Optional kit | 1 | |
| Sentinel X100 quick test kit | 592-900-005 | Optional kit | 1 | |
| High altitude conversion kit, 2,000 to 6,999 ft | 510-811-996 | EG 30-75 | 1 | 2,000 to 6,999 ft |
| High altitude conversion kit, 7,000 to 10,000 ft | 510-811-997 | EG 30-75 | 1 | 7,000 to 10,000 ft |
Source: EG/PEG Series 7 boiler manual, p. 84 (pages 38, 84, 85, 86). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.