Weil-McLain · Boiler · ECO Tec series 3 series

All parts

51 replacement parts that fit the Weil-McLain All, with OEM part numbers, grouped by system.

Condensate

PartPart #QtySize / rating
Condensate trap kit (supplied with boiler)
Condensate tube, 3/16 barb polypropylene, hose clamps
383-700-2681

Other

PartPart #QtySize / rating
Antifreeze, Sentinel X500, 1 gallon592-900-02911 gallon
Corrosion inhibitor, Sentinel X100592-900-0021
Sentinel X100 Quick Test Kit592-900-0051
ECO Tec Quick start kit - Heating only
Includes system temp sensors, Sentinel inhibitor, LWCO probe, Easy-Up manifold, condensate neutralizer, 3in vent termination
383-700-3951
ECO Tec pedestal floor stand383-800-2451
Adjustable floor stand383-800-1021
Wall-mount kit (bracket and hardware)383-200-1151
ECO Tec Easy Up manifold383-700-3431
Low Water Cut-Off511-100-0051
System sensor (pack of 2)383-700-3712
Multi-boiler wiring kit (RS-485 harness)383-700-2721 per boiler
ECO Tec Modbus wiring harness383-700-4011
Condensate neutralizer kit383-500-6311
Relief valve kit (50 psi)383-600-090150 psi
Direct exhaust venting kit (intake/exhaust plates, 2in and 3in screens)383-500-7781
Sidewall vent/air cap termination kit for PVC (sized for 3in PVC)
Needs field 3x2 adapter for 2in pipe
383-500-39713in PVC
Sidewall vent/air cap termination kit for AL29-4C vent and PVC air
Needs field 3x2 adapter for 2in pipe
382-200-43013in SS vent / 3in PVC air
Bird screen, 2in PVC vent and air pipes560-907-72812in
Bird screen, 3in PVC vent and air pipes383-500-10513in
Sidewall separate pipes vent/air termination kit, 3in PVC
Includes two cover plates
383-500-10013in PVC
Sidewall separate pipes vent/air termination kit, 3in AL29-4C SS vent and PVC air
Includes two cover plates
383-700-17213in SS vent / 3in PVC air
PVC concentric vent kit (horizontal or vertical), 3in383-500-35013in PVC
PVC concentric vent kit, 3in (IPEX)
Available from IPEX only
19600613in
M&G Simpson-Duravent PolyPro vertical concentric vent/air kit, 2in / 3in
Black; terra cotta available with -TC suffix. Available from M&G Simpson-Duravent only
2PPS-VK / 3PPS-VK12in / 3in PP
M&G Simpson-Duravent PolyPro sidewall separate air and vent pipes, 2in / 3in
Available from M&G Simpson-Duravent only
2PPS-HTP / 3PPS-HTP12in / 3in PP
M&G Simpson-Duravent 3in PP to 2in PP adapter / 3in PVC to 2in PP adapter3PPS-R2L / 3PPS-03PVCM-2PPF1
Centrotherm INNOFLUE sidewall concentric vent/air kit, 3in / 2in
Available from Centrotherm Eco Systems only
ICWT352 / ICWT24213in / 2in PP
Centrotherm INNOFLUE vertical concentric vent/air kit, 2in / 3in
Available from Centrotherm Eco Systems only
ICRT2439 / ICRT353912in / 3in PP
Centrotherm INNOFLUE 3in to 2in polypropylene adapterISRD03021
Stainless steel vent/flue and air adapter connections (Heat Fab Saf T Vent, Z Flex Z Vent, Metal Fab CORR/Guard)
Listed by manufacturer in order shown
9301PVC / 2SVSAFNS03 / 3CGPVA1
Jacket door, gaskets and labels
Figure 153 item 100
383-800-2461
Gasket kit, bottom, top and sides for jacket door
Figure 153 item 110
383-800-2591
Flue pipe 80mm polypropylene offset
Figure 153 item 120
383-200-110180mm
Top air inlet adapter with internal gasket
Figure 153 item 130
383-200-1121
Top air outlet adapter with internal gasket
Figure 153 item 140
383-700-2751
Air baffle and screws
Figure 153 item 150
383-200-1131
Display gasket / display-to-door gasket
Figure 153 item 160. Text lists one number for both display gaskets; confirm if they differ
383-700-3611
Panel control bracket and cover, with hardware
Figure 153 item 170
383-800-2561
Display board bracket and gaskets
Figure 153 item 180
383-800-2471
Wall-mount bracket, jacket side (with screws)
Figure 153 item 190
383-800-2571
Service gasket, flue/adapter (quantity 2)
Figure 153 item 210
383-700-3842
Service kit, water pipe bracket
Figure 153 item 240
383-200-1201
Burner tube
Figure 155 item 160
383-700-2901
Ignition electrode kit (igniter, gasket and screws)
Figure 155 item 170
383-700-2951
Service gaskets and O-ring kit (silencer gasket, blower gasket, blower O-ring, gas flex line gasket, garlock washer, igniter gasket)
Figure 155 item 180; Figure 157 item 170/180
383-700-3601
Sight glass kit (bracket, glass, gaskets, hardware)
Figure 155 item 190
383-700-1851
Air silencer, clip and gasket
Figure 157 item 100
383-700-2941
Air silencer clip
Figure 157 item 140
383-700-3081
Gas valve assembly
Figure 157 item 150
383-700-3131
Gas line 80/110/150/199
Figure 157 item 160
383-200-1251

Source: ECO Tec Series 3 boiler manual, p. 171 (pages 171, 172, 174, 176). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.