Weil-McLain · Boiler parts
Weil-McLain ECO Tec series 3: parts list
76 replacement parts with OEM part numbers for 14 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Condensate · Other
Condensate
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Condensate trap kit (supplied with boiler) Condensate tube, 3/16 barb polypropylene, hose clamps | 383-700-268 | All | 1 |
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Antifreeze, Sentinel X500, 1 gallon | 592-900-029 | All | 1 | 1 gallon |
| Corrosion inhibitor, Sentinel X100 | 592-900-002 | All | 1 | |
| Sentinel X100 Quick Test Kit | 592-900-005 | All | 1 | |
| ECO Tec Quick start kit - Heating only Includes system temp sensors, Sentinel inhibitor, LWCO probe, Easy-Up manifold, condensate neutralizer, 3in vent termination | 383-700-395 | All | 1 | |
| ECO Tec Quick start kit - Combi Same as heating-only kit plus combi-valve set | 383-700-396 | Combi | 1 | |
| ECO Tec 80/110 maintenance kit Igniter, igniter gasket, venturi gasket, cover plate gasket, venturi-gas valve o-ring, refractory, inhibitor test kit, clips, instructions | 383-700-265 | 80/110 | 1 | |
| ECO Tec 150 maintenance kit Same contents as 80/110 kit | 383-200-102 | 150 | 1 | |
| ECO Tec 199 maintenance kit Same contents as 80/110 kit | 383-700-267 | 199 | 1 | |
| ECO Tec pedestal floor stand | 383-800-245 | All | 1 | |
| Adjustable floor stand | 383-800-102 | All | 1 | |
| Wall-mount kit (bracket and hardware) | 383-200-115 | All | 1 | |
| ECO Tec Easy Up manifold | 383-700-343 | All | 1 | |
| Combi service valve | 383-700-346 | Combi | 1 | |
| Low Water Cut-Off | 511-100-005 | All | 1 | |
| System sensor (pack of 2) | 383-700-371 | All | 2 | |
| Multi-boiler wiring kit (RS-485 harness) | 383-700-272 | All | 1 per boiler | |
| ECO Tec Modbus wiring harness | 383-700-401 | All | 1 | |
| Condensate neutralizer kit | 383-500-631 | All | 1 | |
| Relief valve kit (50 psi) | 383-600-090 | All | 1 | 50 psi |
| Direct exhaust venting kit (intake/exhaust plates, 2in and 3in screens) | 383-500-778 | All | 1 | |
| Sidewall vent/air cap termination kit for PVC (sized for 3in PVC) Needs field 3x2 adapter for 2in pipe | 383-500-397 | All | 1 | 3in PVC |
| Sidewall vent/air cap termination kit for AL29-4C vent and PVC air Needs field 3x2 adapter for 2in pipe | 382-200-430 | All | 1 | 3in SS vent / 3in PVC air |
| Bird screen, 2in PVC vent and air pipes | 560-907-728 | All | 1 | 2in |
| Bird screen, 3in PVC vent and air pipes | 383-500-105 | All | 1 | 3in |
| Sidewall separate pipes vent/air termination kit, 2in PVC Includes two cover plates | 383-700-171 | 80/110/150 only | 1 | 2in PVC |
| Sidewall separate pipes vent/air termination kit, 3in PVC Includes two cover plates | 383-500-100 | All | 1 | 3in PVC |
| Sidewall separate pipes vent/air termination kit, 3in AL29-4C SS vent and PVC air Includes two cover plates | 383-700-172 | All | 1 | 3in SS vent / 3in PVC air |
| PVC concentric vent kit (horizontal or vertical), 2in | 383-700-167 | 80/110/150 only | 1 | 2in PVC |
| PVC concentric vent kit (horizontal or vertical), 3in | 383-500-350 | All | 1 | 3in PVC |
| PVC concentric vent kit, 2in (IPEX) Available from IPEX only | 196005 | 80/110/150 only | 1 | 2in |
| PVC concentric vent kit, 3in (IPEX) Available from IPEX only | 196006 | All | 1 | 3in |
| M&G Simpson-Duravent PolyPro vertical concentric vent/air kit, 2in / 3in Black; terra cotta available with -TC suffix. Available from M&G Simpson-Duravent only | 2PPS-VK / 3PPS-VK | All | 1 | 2in / 3in PP |
| M&G Simpson-Duravent PolyPro sidewall separate air and vent pipes, 2in / 3in Available from M&G Simpson-Duravent only | 2PPS-HTP / 3PPS-HTP | All | 1 | 2in / 3in PP |
| M&G Simpson-Duravent 3in PP to 2in PP adapter / 3in PVC to 2in PP adapter | 3PPS-R2L / 3PPS-03PVCM-2PPF | All | 1 | |
| Centrotherm INNOFLUE sidewall concentric vent/air kit, 3in / 2in Available from Centrotherm Eco Systems only | ICWT352 / ICWT242 | All | 1 | 3in / 2in PP |
| Centrotherm INNOFLUE vertical concentric vent/air kit, 2in / 3in Available from Centrotherm Eco Systems only | ICRT2439 / ICRT3539 | All | 1 | 2in / 3in PP |
| Centrotherm INNOFLUE 3in to 2in polypropylene adapter | ISRD0302 | All | 1 | |
| Stainless steel vent/flue and air adapter connections (Heat Fab Saf T Vent, Z Flex Z Vent, Metal Fab CORR/Guard) Listed by manufacturer in order shown | 9301PVC / 2SVSAFNS03 / 3CGPVA | All | 1 | |
| Jacket door, gaskets and labels Figure 153 item 100 | 383-800-246 | All | 1 | |
| Gasket kit, bottom, top and sides for jacket door Figure 153 item 110 | 383-800-259 | All | 1 | |
| Flue pipe 80mm polypropylene offset Figure 153 item 120 | 383-200-110 | All | 1 | 80mm |
| Top air inlet adapter with internal gasket Figure 153 item 130 | 383-200-112 | All | 1 | |
| Top air outlet adapter with internal gasket Figure 153 item 140 | 383-700-275 | All | 1 | |
| Air baffle and screws Figure 153 item 150 | 383-200-113 | All | 1 | |
| Display gasket / display-to-door gasket Figure 153 item 160. Text lists one number for both display gaskets; confirm if they differ | 383-700-361 | All | 1 | |
| Panel control bracket and cover, with hardware Figure 153 item 170 | 383-800-256 | All | 1 | |
| Display board bracket and gaskets Figure 153 item 180 | 383-800-247 | All | 1 | |
| Wall-mount bracket, jacket side (with screws) Figure 153 item 190 | 383-800-257 | All | 1 | |
| Dome plug, 1-3/8in black (for sealing combi pipe holes) Figure 153 item 200 (not shown) | 383-700-362 | 199 only | 1 | 1-3/8in |
| Service gasket, flue/adapter (quantity 2) Figure 153 item 210 | 383-700-384 | All | 2 | |
| Service kit, cabinet top Figure 153 item 220. Model-to-number order follows the text layout; confirm against the figure | 383-800-248 (80/110), 383-800-249 (150), 383-800-250 (199) | 80/110, 150, 199 | 1 | |
| Service kit, water pipe bracket Figure 153 item 240 | 383-200-120 | All | 1 | |
| Heat exchanger Figure 155 item 100. The text does not clearly map each number to a model; confirm against the model label or the figure | 383-700-284 / 383-700-285 / 383-700-286 | 80, 110, 150 (order as printed) | 1 | |
| Heat exchanger assembly with condensate dish, cover plate, burner, igniter, sight glass, refractory, water sensors, gaskets, silicone and hardware Figure 155 item 110. Includes items 100, 120, 130, 140, 150, 160, 170, 180, 210, 220, 230 | 383-700-287 / 383-200-121 / 383-700-289 | 80/110, 150, 199 (order as printed) | 1 | |
| Insulation with integrated seal, bottom cover plate Figure 155 item 120 | 383-700-291 / 383-200-122 / 383-700-293 | 80/110, 150, 199 (order as printed) | 1 | |
| Burner Figure 155 item 130 | 383-700-297 / 383-700-298 / 383-700-299 | 80/110, 150, 199 (order as printed) | 1 | |
| Disc burner refractory Figure 155 item 140 | 383-700-372 / 383-700-373 | See note | 1 | |
| Burner gasket Figure 155 item 150 | 383-700-300 / 383-700-301 | See note | 1 | |
| Burner tube Figure 155 item 160 | 383-700-290 | All | 1 | |
| Ignition electrode kit (igniter, gasket and screws) Figure 155 item 170 | 383-700-295 | All | 1 | |
| Service gaskets and O-ring kit (silencer gasket, blower gasket, blower O-ring, gas flex line gasket, garlock washer, igniter gasket) Figure 155 item 180; Figure 157 item 170/180 | 383-700-360 | All | 1 | |
| Sight glass kit (bracket, glass, gaskets, hardware) Figure 155 item 190 | 383-700-185 | All | 1 | |
| Condensate dish Figure 155 item 200 | 383-700-331 / 383-700-332 / 383-700-333 | See note | 1 | |
| Condensate dish gasket Figure 155 item 210 | 383-700-381 / 383-700-382 / 383-700-383 | See note | 1 | |
| Flue restrictor Figure 155 item 230 | 383-700-364 | 80/110 (per text layout) | 1 | |
| Top cover insulation and heat exchanger insulation wrap Figure 155 item 240 | 383-700-366 / 383-200-123 / 383-700-368 | 80/110, 150, 199 (order as printed) | 1 | |
| Cover plate Figure 155 item 250 | 383-700-326 / 383-200-124 / 383-700-328 | 80/110, 150, 199 (order as printed) | 1 | |
| Air silencer, clip and gasket Figure 157 item 100 | 383-700-294 | All | 1 | |
| Blower NG40 Figure 157 item 120 | 383-700-303 | 80/110 (per text layout) | 1 | NG40 |
| Blower NG150 or EF90 Figure 157 item 120 | 383-200-103 | 150/199 (per text layout) | 1 | NG150 or EF90 |
| Venturi, natural gas (NG) Figure 157 item 130 | 383-700-305 / 383-700-306 / 383-700-307 | 80/110, 150, 199 (order as printed) | 1 | NG |
| Venturi, propane (LP) Figure 157 item 130. Same numbers as propane conversion kits | 510-811-415 / 510-811-416 / 510-811-417 | 80/110, 150, 199 (order as printed) | 1 | LP |
| Air silencer clip Figure 157 item 140 | 383-700-308 | All | 1 | |
| Gas valve assembly Figure 157 item 150 | 383-700-313 | All | 1 | |
| Gas line 80/110/150/199 Figure 157 item 160 | 383-200-125 | All | 1 |
Source: ECO Tec Series 3 boiler manual, p. 171 (pages 171, 172, 174, 176). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.