Weil-McLain · Boiler · ECO Tec Series 3 series

80/110/150/199 parts

23 replacement parts that fit the Weil-McLain 80/110/150/199, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Direct Exhaust Venting Kit
Includes interior/exterior intake/exhaust plates, 2 in and 3 in vent screens, templates and mounting hardware
383-500-77812 in and 3 in
Air silencer, clip and gasket
Item 100, Figure 157
383-700-2941
Air silencer clip
Item 140
383-700-3081
Gas valve assembly
Item 150
383-700-3131
Gas line
Item 160
383-200-1251
Kit-Service Gaskets/O-Ring ECO Tec (silencer gasket, blower gasket, blower O-ring, garlock washer, igniter gasket)
Item 170 (item number reads as 170 or 180 in the text; the manual cross-references item 180 on page 174)
383-700-3601
Flue temperature sensor & grommet
Item 100
383-500-6001
Outdoor temperature sensor
Item 110
383-500-1251
System temperature sensor
Item 120, two sensors
383-700-3712
Transformer 120V/50V/24V
Item 130
383-700-320150 VA
Display board assembly (circuit board and plastic housing)
Item 140
383-900-3421
Control module assembly (control module and housing)
Item 150. Remove and save all plugs from the original control board; some must be moved to the new board.
383-900-3411
Wire harness — line voltage
Item 160, not shown
383-800-2541
Wire harness — low voltage
Item 170, not shown
383-800-2551
Ignition cable
Item 180, not shown
383-500-6191
Fuse 2.5 A fast blow (qty 5)
Item 190. Shown as "Fuse 2 5 amp" with "Ato 4 amp" in the text; the rating is unclear. Figure 141 on page 160 is referenced. Replaces / alternate: Ato 4 amp fast blow (text reads 'Ato 4 amp').
383-700-36952.5 A fast blow
Jumper for low voltage terminal blocks (five)
Item 200, not shown
383-500-6415
Electrical control connector (eight)
Item 210, not shown
383-900-1118
Low voltage sealed wire grommet
Item 220, seals thermostat wire at cabinet entrance
383-700-3851
Harness - display to control module
Item 240, not shown
383-800-2581
Harness - Modbus wiring
Item 270, not shown
383-700-4011
Relief valve 30 PSIG (shipped loose for field installation)
Item 280
383-500-095130 PSIG
Pressure & temperature gauge (shipped loose for field installation)
Item 290
380-000-0001

Source: ECO Tec Series 3 boiler manual, p. 178 (pages 45, 176, 180). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.