Rinnai · Boiler · E-Combi series

E110CRN parts

246 replacement parts that fit the Rinnai E110CRN, with OEM part numbers, grouped by system.

Controls & boards

PartPart #QtySize / rating
Control unit casing, back8090000931
Control unit MCBA 5417 E RAC8050000251
Control unit casing, front8090000941

Ignition & flame

PartPart #QtySize / rating
Gasket, ionisation/ignition electrode8090000201
Ignition electrode with gasket8050000361
Ignition cable8050000371
Ionisation wire8050000391

Gas valve & orifices

PartPart #QtySize / rating
Gasket, gas valve to venturi8090000171
Gasket, venturi to fan8090000181
Venturi
OSS2
8070000141
Cover, gas valve8090000461
O-ring 21.89x2.62 gas line8090000611
Gasket, 3/4 in. gas valve fitting8090000621
Gas pipe E110C8060000211
Gas fitting OSS1/28060000151
O-ring 13.94x2.62 (yellow silicone)8090000551
Gas valve fitting 3/4 in.8060000161
Gas valve8060000191

Pressure & limit switches

PartPart #QtySize / rating
Safety (relief) valve 3/4 in. NPT8070000771
Flow switch 2.5 L
Optional on some models
8050000431
High limit switch8050000331

Electrical

PartPart #QtySize / rating
Wiring harness8050000411
Terminal connection sticker8050000461
Connector 2-pole purple8050000151
Connector 3-pole gray8050000181
Connector 4-pole brown8050000211
Connector 2-pole black8050000161
Connector 6-pole blue8050000221
Transformer 120 V / 24 V8050000101
Screw 3.5x9.58050000115 per pack
Fuse 5 A fast8050000263 per pack
Fuse 4 A slow-blow (250 V)8050000273 per pack
Wiring harness, DHW8050000421
Fan harness 120 V8050000381

Motors & blowers

PartPart #QtySize / rating
Damper
OSS2
8070000171
Fan NRG 118 (OSS1/2)8080000201

Inducer & venting

PartPart #QtySize / rating
Room air filter
Needed for room air combustion
8080000251
Air supply cover 80 mm
Spare parts list item 77
8070000751
Concentric flue adapter 80/125 mm
Spare parts list item 78
8080000231
Air intake gasket 80 mm
Spare parts list item 80
8090000471
Flue gas connector 3 in.
Spare parts list item 81
8080000301
Air intake connector 3 in.
Spare parts list item 82
8080000311
Flue gas pipe, OSS2/3/4 variant
Spare parts list item 83; OSS1/OSS2 variant to model mapping inferred from X-count in table
8080000331
Measuring point plug, parallel flue pipe
Spare parts list item 84
8080000281
PP flue gas pipe gasket, OSS2/3/4 variant
Spare parts list item 85; OSS1/OSS2 variant to model mapping inferred from X-count in table
8090000481
Air supply gasket 125 mm
Spare parts list item 86
8090000491
Lip ring 80 mm8090000391
DGV 3/5 in. concentric air intake tee
Third-party vent product listed as approved: Heatfab
DGV03TAD31
DGV 3/5 in. concentric 12 in. length
Third-party vent product listed as approved: Heatfab
DGV03L121
DGV 3/5 in. concentric 31 in. length
Third-party vent product listed as approved: Heatfab
DGV03L361
DGV 3/5 in. concentric horizontal termination adapter
Third-party vent product listed as approved: Heatfab
DGV03HT1
DGV 3/5 in. concentric vertical termination adapter
Third-party vent product listed as approved: Heatfab
DGV03VT1
Rain cap
Third-party vent product listed as approved: Heatfab
SGV3001
3 in. 12 in. length
Third-party vent product listed as approved: Heatfab
SGV3021
3 in. 31 in. length
Third-party vent product listed as approved: Heatfab
SGV3071
3 in. 90 deg elbow
Third-party vent product listed as approved: Heatfab
SGV3141
3 in. screen termination
Third-party vent product listed as approved: Heatfab
SGV3921
3 in. round wall thimble plate
Third-party vent product listed as approved: Heatfab
SGV3931
3 in. tall cone flashing, flat 2/12 pitch
Third-party vent product listed as approved: Heatfab
SGV3TCF1
Concentric vent termination
Third-party vent product listed as approved: IPEX
1CT03031
Termination vent screen
Third-party vent product listed as approved: IPEX
1960511
3 in. stainless flex lining system
Third-party vent product listed as approved: Simpson Dura-Vent
2945901
3 in. FasNSeal flex-to-FasNSeal adapter, female
Third-party vent product listed as approved: Simpson Dura-Vent
3040031
3 in. FasNSeal-to-FasNSeal adapter, flexible male
Third-party vent product listed as approved: Simpson Dura-Vent
3041031
80 mm to 3 in. appliance adapter
Third-party vent product listed as approved: Simpson Dura-Vent
FSA-80MM31
Vertical termination
Third-party vent product listed as approved: Simpson Dura-Vent
3003251
3 in. 90 deg bend
Third-party vent product listed as approved: Simpson Dura-Vent
3001601
3x5 concentric 12 in. straight pipe
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-121
3x5 concentric 36 in. straight pipe
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-361
3x5 concentric 48 in. straight pipe
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-481
3x5 concentric 90 deg elbow
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-E901
3x5 concentric 45 deg elbow
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-E451
3x5 concentric wall strap
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-WS1
3x5 concentric horizontal cap
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-HC1
3x5 concentric vertical cap
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-VC1
3x5 sealed combustion 6 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-06031
3x5 sealed combustion 12 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-12031
3x5 sealed combustion 18 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-18031
3x5 sealed combustion 24 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-24031
3x5 sealed combustion 36 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-36-31
3x5 sealed combustion adjustable vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-AVL31
3x5 sealed combustion 94 deg elbow
Third-party vent product listed as approved: Simpson Dura-Vent
SC-940331
2 in. (60 mm) twin pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-HTP1
2 in. (60 mm) single pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-HST1
2 in. (60 mm) flex pipe
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-FLEX XX1
2 in. (60 mm) 90 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-E901
2 in. (60 mm) 45 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-E451
2 in. (60 mm) single-wall pipe 12 in.
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-121
2 in. (60 mm) single-wall pipe 36 in.
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-361
2 in. (60 mm) single-wall pipe 72 in.
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-721
3 in. (80 mm) twin pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-HTP1
3 in. (80 mm) single pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-HST1
3 in. (80 mm) flex pipe
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-FLEX XX1
3 in. (80 mm) 90 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-E901
3 in. (80 mm) 45 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-E451
3 in. (80 mm) single-wall pipe 12 in.
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-121
3 in. (80 mm) single-wall pipe 36 in.
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-361
3 in. (80 mm) single-wall pipe 72 in.
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-721
4 in. (100 mm) flex pipe
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-FLEX XX1
4 in. (100 mm) 90 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-E901
4 in. (100 mm) 45 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-E451
4 in. (100 mm) single-wall pipe 12 in.
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-121
4 in. (100 mm) single-wall pipe 36 in.
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-361
4 in. (100 mm) single-wall pipe 72 in.
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-721
1 m section PP/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
2240801
90 deg male x female PP/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
2240781
Horizontal PP termination 21 in.
Third-party vent product listed as approved: Rinnai/Ubbink
2231751
Vertical PP termination
Third-party vent product listed as approved: Rinnai/Ubbink
1841621
45 deg vent elbow (2 pcs)
Third-party vent product listed as approved: Rinnai/Ubbink
224077PP1
1 m section SS/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
224204SS1
90 deg male x female SS/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
224201SS1
Horizontal SS termination 21 in.
Third-party vent product listed as approved: Rinnai/Ubbink
223178SS1
Vertical SS termination
Third-party vent product listed as approved: Rinnai/Ubbink
184221SS1
3/4 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC03041
3/5 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC03051
3/6 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC03061
3/7 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC03071
3 in. connector ring
Third-party vent product listed as approved: CentroTherm
IANS031
3 in. support clamp
Third-party vent product listed as approved: CentroTherm
IASC031
3 in. spacer
Third-party vent product listed as approved: CentroTherm
IASP031
3 in. screen PPs-UV black
Third-party vent product listed as approved: CentroTherm
IASPP031
3 in. bird screen SS
Third-party vent product listed as approved: CentroTherm
IASSS031
3 in. wall plate black
Third-party vent product listed as approved: CentroTherm
IAWP03B1
3 in. wall plate white
Third-party vent product listed as approved: CentroTherm
IAWP03W1
3 in. twin pipe to 3/5 in. concentric adaptor
Third-party vent product listed as approved: CentroTherm
ICTC03351
3 in. base support
Third-party vent product listed as approved: CentroTherm
ISBS03871
3 in. chimney cover SS with PPs-UV end pipe
Third-party vent product listed as approved: CentroTherm
ISCM031
3 in. chimney cover PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISCP031
3 in. chimney cover SS with SS end pipe
Third-party vent product listed as approved: CentroTherm
ISCS031
3 in. 45 deg elbow
Third-party vent product listed as approved: CentroTherm
ISEL03451
3 in. 87 deg elbow
Third-party vent product listed as approved: CentroTherm
ISEL03871
3 in. 45 deg elbow long
Third-party vent product listed as approved: CentroTherm
ISELL03451
3 in. 45 deg elbow long PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISELL0345UV1
3 in. 87 deg elbow long
Third-party vent product listed as approved: CentroTherm
ISELL03871
3 in. 87 deg elbow long PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISELL0387UV1
3 in. 87 deg sweep elbow
Third-party vent product listed as approved: CentroTherm
ISELR03871
3 in. x 20 in. end pipe PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISEP031
3 in. x 39 in. end pipe PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISEP03391
3 in. single-wall EPDM gasket
Third-party vent product listed as approved: CentroTherm
ISGE031
3 in. horizontal drain tee
Third-party vent product listed as approved: CentroTherm
ISHDT031
3 in. low profile wall termination
Third-party vent product listed as approved: CentroTherm
ISLPT03031
3 in. tee
Third-party vent product listed as approved: CentroTherm
IST031
3 in. test port
Third-party vent product listed as approved: CentroTherm
ISTP031
3 in. termination tee long
Third-party vent product listed as approved: CentroTherm
ISTT03201
3 in. x 12 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL0311
3 in. x 24 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL0321
3 in. x 24 in. vent length PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISVL032UV1
3 in. x 36 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL0331
3 in. x 39 in. vent length UV black
Third-party vent product listed as approved: CentroTherm
ISVL0339UV1
3 in. x 72 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL0361
3/5 in. concentric roof termination PPs-UV
Third-party vent product listed as approved: CentroTherm
ICRT35391
3/5 in. concentric wall termination PPs-UV
Third-party vent product listed as approved: CentroTherm
ICWT3521
3 in. to 2 in. velocity cone
Third-party vent product listed as approved: CentroTherm
ISVC03021

Heat exchanger & burners

PartPart #QtySize / rating
Clamp bar, heat exchanger top (long)8090000141
Heat exchanger top section set
OSS2
8070000111
Bolt M5x168090000155 per pack
Gasket, fan to heat exchanger top8090000161
Bolt M5x128090000195 per pack
Gasket, silencer to venturi8090000211
Heat exchanger (ASME)
OSS2
8070000201
Gasket, heat exchanger to top section
OSS2
8090000311
Gasket, burner to top section
OSS2
8090000341
Burner cassette set
OSS2
8060000111
Insulation pipe plate set (left + right)8090000361
O-ring 17.12x2.62 for heat exchanger plug8090001033 per pack
Metal plug for heat exchanger, 1/2 in.8090001151

Condensate

PartPart #QtySize / rating
Condensate neutralizer kit
Optional
8040000741
Condensate trap, complete
Replace if the trap leaks
8090001001
Gasket, condensate tray
OSS2
8090000261
Condensate tray
OSS2
8090000421
Clamp bar, condensate tray8090000441
Condensate collector8090000811
O-ring 40x3.53 trap tray8090000841
O-ring 18.72x2.62 EPDM8090000523 per pack

Water / hydronic

PartPart #QtySize / rating
O-ring 5.00x2.00 for flow sensor8090000805 per pack
De-aerator cap8070000233 per pack
De-aerator (chrome)8070000241
O-ring 13.94x2.62 for de-aerator8090000282 per pack
Cold water pipe bend 15 mm
Optional on some models
8070000821
Cold water pipe 15 mm8070000831
Connection set 1/2 in. x 3/4 in. NPT incl. flow restrictor (green)
E110
8070000731
Compression nut 1/2 in. brass, 15 mm8090000701
Compression ferrule 15 mm8090000691
Return pipe to 3-way valve with filter8070000491
Connection set 22 mm x 3/4 in. NPT8070000691
Return pipe filter8070000291
Filter cap, pressure equalisation tube connection8070001211
O-ring 25.07x2.62 for 3-way valve8090000581
Nut M35 (30 mm)8090000591
Hot water pipe 15 mm8070000531
Plate heat exchanger 35 kW8070000551
O-ring 21.89x2.62 EPDM (central heating)8090000882 per pack
Flow pipe, plate exchanger to CH (E110C)8070001251
Pipe 3-way valve to pump8070000601
O-ring 26.70x1.788090000913 per pack
Fitting set, 3-way valve8070000621
3-way valve housing O-ring8090000571
3-way valve cartridge8070000301
3-way valve flange8070000631
Pipe plate exchanger to 3-way valve8070000641
Pressure equalisation tube8070001221
Connection set 15 mm x 3/4 in. M-NPT8070000681
O-ring 29.74x3.53 flow/return8090000642 per pack
Temperature/pressure gauge 1/4 in. NPT with lock8070000811
3-way valve actuator VC20108050000301

Cabinet & doors

PartPart #QtySize / rating
Casing gasket
Spare parts list item 1
8090000731
Casing set
Spare parts list item 2
8090000741
Boiler cover bolts, set of 5 (M5x20)
Spare parts list item 3
8090001271
Casing door spring
Spare parts list item 4
8090000751
Controls gasket
Spare parts list item 5
8090000761
Casing door
Spare parts list item 6
8090000771
Wall bracket (also for Q85S, Q130S)
Spare parts list item 76
8090000651
Quick release, small
Spare parts list item 87
8090000781
Quick release, large
Spare parts list item 88
8090000791

Other

PartPart #QtySize / rating
Fitting kit, complete
Part number order inferred from column order in the kit table
8040000471
Low loss header plumbing kit
For zone pump systems or high system pressure drop
8040000611
User manual
Spare parts list item 7
8000000121
Installation manual
Spare parts list item 8
8000000131
Screw Taptite M5x88090000223 per pack
Boiler tool kit8090000241
Flue gas sensor plug8090000401
Bolt M5x12 hex socket8090000453 per pack
T-piece for T3 sensor8070000481
Bolt M6x20 stainless8090000893 per pack
Pump gasket8090000562 per pack
Pump UPER 20-78, 120 V8070001271
NTC sensor T2/T38050000321
Water pressure sensor8050000341
Water pressure sensor cable8050000501
NTC sensor T1/T38050000351
Outdoor reset sensor ARV128050000471
PVC FGV concentric kit
Third-party vent product listed as approved: IPEX
1960061
PVC FGV wall termination kit
Third-party vent product listed as approved: IPEX
812191
CPVC FGV concentric vent kit
Third-party vent product listed as approved: IPEX
1970091
Wall kit with cap
Third-party vent product listed as approved: Simpson Dura-Vent
FSSCWMK351
Roof kit with cap
Third-party vent product listed as approved: Simpson Dura-Vent
FSSCTRK351
2 in. (60 mm) concentric horizontal termination kit
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-HK1
2 in. (60 mm) concentric vertical termination cap kit
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-VK1
2 in. (60 mm) flex chimney lining kit
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-FK1
3 in. (80 mm) concentric horizontal termination kit
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-HK1
3 in. (80 mm) concentric vertical termination cap kit
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-VK1
3 in. (80 mm) flex chimney lining kit
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-FK1
4 in. (100 mm) concentric horizontal termination kit
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-HK1
4 in. (100 mm) concentric vertical termination cap kit
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-VK1
4 in. (100 mm) flex chimney lining kit
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-FK1
Raised horizontal termination snorkel kit
Third-party vent product listed as approved: Rinnai/Ubbink
224047PP1

Same series

The E-Combi parts list shows every part for all 8 models side by side. Other models: E110CR, E110CRP, E50CR, E50CRN, E75CR, E75CRN, E75CRP.

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116) (pages 9, 18, 26, 67, 80, 82, 84, 86). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.