Rinnai · Boiler parts

Rinnai E-Combi condensing combi boiler (E50CRN, E75CRN/CRP, E110CRN/CRP): parts list

275 replacement parts with OEM part numbers for 8 models. Pick your model for a list of only the parts that fit it.

Jump to: Controls & boards · Ignition & flame · Gas valve & orifices · Pressure & limit switches · Electrical · Motors & blowers · Inducer & venting · Heat exchanger & burners · Condensate · Water / hydronic · Cabinet & doors · Other

Controls & boards

PartPart #FitsQtySize / rating
Control unit casing, back809000093All 8 models1
Control unit MCBA 5417 E RAC805000025All 8 models1
Control unit casing, front809000094All 8 models1

Ignition & flame

PartPart #FitsQtySize / rating
Gasket, ionisation/ignition electrode809000020All 8 models1
Ignition electrode with gasket805000036All 8 models1
Ignition cable805000037All 8 models1
Ionisation wire805000039All 8 models1

Gas valve & orifices

PartPart #FitsQtySize / rating
Propane conversion kit803000014E50CR1
Propane conversion kit804000015E75CR1
Propane conversion kit804000016E110CR1
Natural gas conversion kit804000023E75CR1
Natural gas conversion kit804000024E110CR1
Gasket, gas valve to venturi809000017All 8 models1
Gasket, venturi to fan809000018All 8 models1
Venturi
OSS1
807000013E50CRN, E75CRN, E75CRP1
Venturi
OSS2
807000014E110CRN, E110CRP1
Cover, gas valve809000046All 8 models1
O-ring 21.89x2.62 gas line809000061All 8 models1
Gasket, 3/4 in. gas valve fitting809000062All 8 models1
Gas pipe E75C806000020E50CRN, E75CRN, E75CRP1
Gas pipe E110C806000021E110CRN, E110CRP1
Gas fitting OSS1/2806000015All 8 models1
O-ring 13.94x2.62 (yellow silicone)809000055All 8 models1
Gas valve fitting 3/4 in.806000016All 8 models1
Gas valve806000019All 8 models1

Pressure & limit switches

PartPart #FitsQtySize / rating
Safety (relief) valve 3/4 in. NPT807000077All 8 models1
Flow switch 2.5 L
Optional on some models
805000043E75CRN, E75CRP, E110CRN, E110CRP1
High limit switch805000033All 8 models1

Electrical

PartPart #FitsQtySize / rating
Wiring harness805000041All 8 models1
Terminal connection sticker805000046All 8 models1
Connector 2-pole purple805000015All 8 models1
Connector 3-pole gray805000018All 8 models1
Connector 4-pole brown805000021All 8 models1
Connector 2-pole black805000016All 8 models1
Connector 6-pole blue805000022All 8 models1
Transformer 120 V / 24 V805000010All 8 models1
Screw 3.5x9.5805000011All 8 models5 per pack
Fuse 5 A fast805000026All 8 models3 per pack
Fuse 4 A slow-blow (250 V)805000027All 8 models3 per pack
Wiring harness, DHW805000042All 8 models1
Fan harness 120 V805000038All 8 models1

Motors & blowers

PartPart #FitsQtySize / rating
Damper
OSS1
807000016E50CRN, E75CRN, E75CRP1
Damper
OSS2
807000017E110CRN, E110CRP1
Fan NRG 118 (OSS1/2)808000020All 8 models1

Inducer & venting

PartPart #FitsQtySize / rating
Concentric vent adapter 80/125 mm (parallel to concentric conversion)
Also listed as spare item 78
808000023E50CRN1
Room air filter
Needed for room air combustion
808000025All 8 models1
Air supply cover 80 mm
Spare parts list item 77
807000075All 8 models1
Concentric flue adapter 80/125 mm
Spare parts list item 78
808000023All 8 models1
Air intake gasket 80 mm
Spare parts list item 80
809000047All 8 models1
Flue gas connector 3 in.
Spare parts list item 81
808000030All 8 models1
Air intake connector 3 in.
Spare parts list item 82
808000031All 8 models1
Flue gas pipe, OSS1 variant
Spare parts list item 83; OSS1/OSS2 variant to model mapping inferred from X-count in table
808000032E50CRN, E75CRN, E75CRP1
Flue gas pipe, OSS2/3/4 variant
Spare parts list item 83; OSS1/OSS2 variant to model mapping inferred from X-count in table
808000033E110CRN, E110CRP1
Measuring point plug, parallel flue pipe
Spare parts list item 84
808000028All 8 models1
PP flue gas pipe gasket, OSS1 variant
Spare parts list item 85; OSS1/OSS2 variant to model mapping inferred from X-count in table
808000034E50CRN, E75CRN, E75CRP1
PP flue gas pipe gasket, OSS2/3/4 variant
Spare parts list item 85; OSS1/OSS2 variant to model mapping inferred from X-count in table
809000048E110CRN, E110CRP1
Air supply gasket 125 mm
Spare parts list item 86
809000049All 8 models1
Lip ring 63 mm809000038E50CRN, E75CRN, E75CRP1
Lip ring 80 mm809000039E110CRN, E110CRP1
DGV 3/5 in. concentric air intake tee
Third-party vent product listed as approved: Heatfab
DGV03TAD3All 8 models1
DGV 3/5 in. concentric 12 in. length
Third-party vent product listed as approved: Heatfab
DGV03L12All 8 models1
DGV 3/5 in. concentric 31 in. length
Third-party vent product listed as approved: Heatfab
DGV03L36All 8 models1
DGV 3/5 in. concentric horizontal termination adapter
Third-party vent product listed as approved: Heatfab
DGV03HTAll 8 models1
DGV 3/5 in. concentric vertical termination adapter
Third-party vent product listed as approved: Heatfab
DGV03VTAll 8 models1
Rain cap
Third-party vent product listed as approved: Heatfab
SGV300All 8 models1
3 in. 12 in. length
Third-party vent product listed as approved: Heatfab
SGV302All 8 models1
3 in. 31 in. length
Third-party vent product listed as approved: Heatfab
SGV307All 8 models1
3 in. 90 deg elbow
Third-party vent product listed as approved: Heatfab
SGV314All 8 models1
3 in. screen termination
Third-party vent product listed as approved: Heatfab
SGV392All 8 models1
3 in. round wall thimble plate
Third-party vent product listed as approved: Heatfab
SGV393All 8 models1
3 in. tall cone flashing, flat 2/12 pitch
Third-party vent product listed as approved: Heatfab
SGV3TCFAll 8 models1
Concentric vent termination
Third-party vent product listed as approved: IPEX
1CT0303All 8 models1
Termination vent screen
Third-party vent product listed as approved: IPEX
196051All 8 models1
3 in. stainless flex lining system
Third-party vent product listed as approved: Simpson Dura-Vent
294590All 8 models1
3 in. FasNSeal flex-to-FasNSeal adapter, female
Third-party vent product listed as approved: Simpson Dura-Vent
304003All 8 models1
3 in. FasNSeal-to-FasNSeal adapter, flexible male
Third-party vent product listed as approved: Simpson Dura-Vent
304103All 8 models1
80 mm to 3 in. appliance adapter
Third-party vent product listed as approved: Simpson Dura-Vent
FSA-80MM3All 8 models1
Vertical termination
Third-party vent product listed as approved: Simpson Dura-Vent
300325All 8 models1
3 in. 90 deg bend
Third-party vent product listed as approved: Simpson Dura-Vent
300160All 8 models1
3x5 concentric 12 in. straight pipe
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-12All 8 models1
3x5 concentric 36 in. straight pipe
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-36All 8 models1
3x5 concentric 48 in. straight pipe
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-48All 8 models1
3x5 concentric 90 deg elbow
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-E90All 8 models1
3x5 concentric 45 deg elbow
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-E45All 8 models1
3x5 concentric wall strap
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-WSAll 8 models1
3x5 concentric horizontal cap
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-HCAll 8 models1
3x5 concentric vertical cap
Third-party vent product listed as approved: Simpson Dura-Vent
35CVS-VCAll 8 models1
3x5 sealed combustion 6 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-0603All 8 models1
3x5 sealed combustion 12 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-1203All 8 models1
3x5 sealed combustion 18 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-1803All 8 models1
3x5 sealed combustion 24 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-2403All 8 models1
3x5 sealed combustion 36 in. vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-36-3All 8 models1
3x5 sealed combustion adjustable vent length
Third-party vent product listed as approved: Simpson Dura-Vent
SC-AVL3All 8 models1
3x5 sealed combustion 94 deg elbow
Third-party vent product listed as approved: Simpson Dura-Vent
SC-94033All 8 models1
2 in. (60 mm) twin pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-HTPAll 8 models1
2 in. (60 mm) single pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-HSTAll 8 models1
2 in. (60 mm) flex pipe
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-FLEX XXAll 8 models1
2 in. (60 mm) 90 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-E90All 8 models1
2 in. (60 mm) 45 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-E45All 8 models1
2 in. (60 mm) single-wall pipe 12 in.
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-12All 8 models1
2 in. (60 mm) single-wall pipe 36 in.
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-36All 8 models1
2 in. (60 mm) single-wall pipe 72 in.
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-72All 8 models1
3 in. (80 mm) twin pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-HTPAll 8 models1
3 in. (80 mm) single pipe termination
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-HSTAll 8 models1
3 in. (80 mm) flex pipe
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-FLEX XXAll 8 models1
3 in. (80 mm) 90 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-E90All 8 models1
3 in. (80 mm) 45 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-E45All 8 models1
3 in. (80 mm) single-wall pipe 12 in.
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-12All 8 models1
3 in. (80 mm) single-wall pipe 36 in.
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-36All 8 models1
3 in. (80 mm) single-wall pipe 72 in.
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-72All 8 models1
4 in. (100 mm) flex pipe
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-FLEX XXAll 8 models1
4 in. (100 mm) 90 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-E90All 8 models1
4 in. (100 mm) 45 deg elbow
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-E45All 8 models1
4 in. (100 mm) single-wall pipe 12 in.
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-12All 8 models1
4 in. (100 mm) single-wall pipe 36 in.
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-36All 8 models1
4 in. (100 mm) single-wall pipe 72 in.
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-72All 8 models1
1 m section PP/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
224080All 8 models1
90 deg male x female PP/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
224078All 8 models1
Horizontal PP termination 21 in.
Third-party vent product listed as approved: Rinnai/Ubbink
223175All 8 models1
Vertical PP termination
Third-party vent product listed as approved: Rinnai/Ubbink
184162All 8 models1
45 deg vent elbow (2 pcs)
Third-party vent product listed as approved: Rinnai/Ubbink
224077PPAll 8 models1
1 m section SS/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
224204SSAll 8 models1
90 deg male x female SS/PVC 3/5 in.
Third-party vent product listed as approved: Rinnai/Ubbink
224201SSAll 8 models1
Horizontal SS termination 21 in.
Third-party vent product listed as approved: Rinnai/Ubbink
223178SSAll 8 models1
Vertical SS termination
Third-party vent product listed as approved: Rinnai/Ubbink
184221SSAll 8 models1
3/4 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC0304All 8 models1
3/5 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC0305All 8 models1
3/6 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC0306All 8 models1
3/7 in. B-vent chimney cover
Third-party vent product listed as approved: CentroTherm
IABC0307All 8 models1
3 in. connector ring
Third-party vent product listed as approved: CentroTherm
IANS03All 8 models1
3 in. support clamp
Third-party vent product listed as approved: CentroTherm
IASC03All 8 models1
3 in. spacer
Third-party vent product listed as approved: CentroTherm
IASP03All 8 models1
3 in. screen PPs-UV black
Third-party vent product listed as approved: CentroTherm
IASPP03All 8 models1
3 in. bird screen SS
Third-party vent product listed as approved: CentroTherm
IASSS03All 8 models1
3 in. wall plate black
Third-party vent product listed as approved: CentroTherm
IAWP03BAll 8 models1
3 in. wall plate white
Third-party vent product listed as approved: CentroTherm
IAWP03WAll 8 models1
3 in. twin pipe to 3/5 in. concentric adaptor
Third-party vent product listed as approved: CentroTherm
ICTC0335All 8 models1
3 in. base support
Third-party vent product listed as approved: CentroTherm
ISBS0387All 8 models1
3 in. chimney cover SS with PPs-UV end pipe
Third-party vent product listed as approved: CentroTherm
ISCM03All 8 models1
3 in. chimney cover PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISCP03All 8 models1
3 in. chimney cover SS with SS end pipe
Third-party vent product listed as approved: CentroTherm
ISCS03All 8 models1
3 in. 45 deg elbow
Third-party vent product listed as approved: CentroTherm
ISEL0345All 8 models1
3 in. 87 deg elbow
Third-party vent product listed as approved: CentroTherm
ISEL0387All 8 models1
3 in. 45 deg elbow long
Third-party vent product listed as approved: CentroTherm
ISELL0345All 8 models1
3 in. 45 deg elbow long PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISELL0345UVAll 8 models1
3 in. 87 deg elbow long
Third-party vent product listed as approved: CentroTherm
ISELL0387All 8 models1
3 in. 87 deg elbow long PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISELL0387UVAll 8 models1
3 in. 87 deg sweep elbow
Third-party vent product listed as approved: CentroTherm
ISELR0387All 8 models1
3 in. x 20 in. end pipe PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISEP03All 8 models1
3 in. x 39 in. end pipe PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISEP0339All 8 models1
3 in. single-wall EPDM gasket
Third-party vent product listed as approved: CentroTherm
ISGE03All 8 models1
3 in. horizontal drain tee
Third-party vent product listed as approved: CentroTherm
ISHDT03All 8 models1
3 in. low profile wall termination
Third-party vent product listed as approved: CentroTherm
ISLPT0303All 8 models1
3 in. tee
Third-party vent product listed as approved: CentroTherm
IST03All 8 models1
3 in. test port
Third-party vent product listed as approved: CentroTherm
ISTP03All 8 models1
3 in. termination tee long
Third-party vent product listed as approved: CentroTherm
ISTT0320All 8 models1
3 in. x 12 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL031All 8 models1
3 in. x 24 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL032All 8 models1
3 in. x 24 in. vent length PPs-UV black
Third-party vent product listed as approved: CentroTherm
ISVL032UVAll 8 models1
3 in. x 36 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL033All 8 models1
3 in. x 39 in. vent length UV black
Third-party vent product listed as approved: CentroTherm
ISVL0339UVAll 8 models1
3 in. x 72 in. vent length
Third-party vent product listed as approved: CentroTherm
ISVL036All 8 models1
3/5 in. concentric roof termination PPs-UV
Third-party vent product listed as approved: CentroTherm
ICRT3539All 8 models1
3/5 in. concentric wall termination PPs-UV
Third-party vent product listed as approved: CentroTherm
ICWT352All 8 models1
3 in. to 2 in. velocity cone
Third-party vent product listed as approved: CentroTherm
ISVC0302All 8 models1

Heat exchanger & burners

PartPart #FitsQtySize / rating
Clamp bar, heat exchanger top (long)809000014All 8 models1
Heat exchanger top section set
OSS1
807000010E50CRN, E75CRN, E75CRP1
Heat exchanger top section set
OSS2
807000011E110CRN, E110CRP1
Bolt M5x16809000015All 8 models5 per pack
Gasket, fan to heat exchanger top809000016All 8 models1
Bolt M5x12809000019All 8 models5 per pack
Gasket, silencer to venturi809000021All 8 models1
Heat exchanger (ASME)
OSS1
807000019E50CRN, E75CRN, E75CRP1
Heat exchanger (ASME)
OSS2
807000020E110CRN, E110CRP1
Gasket, heat exchanger to top section
OSS1
809000030E50CRN, E75CRN, E75CRP1
Gasket, heat exchanger to top section
OSS2
809000031E110CRN, E110CRP1
Gasket, burner to top section
OSS1
809000033E50CRN, E75CRN, E75CRP1
Gasket, burner to top section
OSS2
809000034E110CRN, E110CRP1
Burner cassette set
OSS1
806000010E50CRN, E75CRN, E75CRP1
Burner cassette set
OSS2
806000011E110CRN, E110CRP1
Insulation pipe plate set (left + right)809000036All 8 models1
O-ring 17.12x2.62 for heat exchanger plug809000103All 8 models3 per pack
Metal plug for heat exchanger, 1/2 in.809000115All 8 models1

Condensate

PartPart #FitsQtySize / rating
Condensate neutralizer kit
Optional
804000074All 8 models1
Condensate trap, complete
Replace if the trap leaks
809000100All 8 models1
Gasket, condensate tray
OSS1
809000025E50CRN, E75CRN, E75CRP1
Gasket, condensate tray
OSS2
809000026E110CRN, E110CRP1
Condensate tray
OSS1
809000041E50CRN, E75CRN, E75CRP1
Condensate tray
OSS2
809000042E110CRN, E110CRP1
Clamp bar, condensate tray809000044All 8 models1
Condensate collector809000081All 8 models1
O-ring 40x3.53 trap tray809000084All 8 models1
O-ring 18.72x2.62 EPDM809000052All 8 models3 per pack

Water / hydronic

PartPart #FitsQtySize / rating
O-ring 5.00x2.00 for flow sensor809000080All 8 models5 per pack
De-aerator cap807000023All 8 models3 per pack
De-aerator (chrome)807000024All 8 models1
O-ring 13.94x2.62 for de-aerator809000028All 8 models2 per pack
Cold water pipe bend 15 mm (E50C)807000119E50CRN1
Cold water pipe bend 15 mm
Optional on some models
807000082E75CRN, E75CRP, E110CRN, E110CRP1
Cold water pipe 15 mm807000083All 8 models1
Connection set 15 mm x 3/4 in. NPT incl. flow restrictor (brown)
E50/E75
807000072E50CRN, E75CRN, E75CRP1
Connection set 1/2 in. x 3/4 in. NPT incl. flow restrictor (green)
E110
807000073E110CRN, E110CRP1
Socket fitting 15 mm809000144E50CRN1
Compression nut 1/2 in. brass, 15 mm809000070All 8 models1
Compression ferrule 15 mm809000069All 8 models1
Return pipe to 3-way valve with filter807000049All 8 models1
Connection set 22 mm x 3/4 in. NPT807000069All 8 models1
Return pipe filter807000029All 8 models1
Filter cap, pressure equalisation tube connection807000121All 8 models1
O-ring 25.07x2.62 for 3-way valve809000058All 8 models1
Nut M35 (30 mm)809000059All 8 models1
Hot water pipe 15 mm807000053All 8 models1
Plate heat exchanger 24 kW807000054E50CRN, E75CRN, E75CRP1
Plate heat exchanger 35 kW807000055E110CRN, E110CRP1
O-ring 21.89x2.62 EPDM (central heating)809000088All 8 models2 per pack
Flow pipe, plate exchanger to CH (E75 & E50C)807000058E50CRN, E75CRN, E75CRP1
Flow pipe, plate exchanger to CH (E110C)807000125E110CRN, E110CRP1
Pipe 3-way valve to pump807000060All 8 models1
O-ring 26.70x1.78809000091All 8 models3 per pack
Fitting set, 3-way valve807000062All 8 models1
3-way valve housing O-ring809000057All 8 models1
3-way valve cartridge807000030All 8 models1
3-way valve flange807000063All 8 models1
Pipe plate exchanger to 3-way valve807000064All 8 models1
Pressure equalisation tube807000122All 8 models1
Connection set 15 mm x 3/4 in. M-NPT807000068All 8 models1
O-ring 29.74x3.53 flow/return809000064All 8 models2 per pack
Temperature/pressure gauge 1/4 in. NPT with lock807000081All 8 models1
3-way valve actuator VC2010805000030All 8 models1

Cabinet & doors

PartPart #FitsQtySize / rating
Casing gasket
Spare parts list item 1
809000073All 8 models1
Casing set
Spare parts list item 2
809000074All 8 models1
Boiler cover bolts, set of 5 (M5x20)
Spare parts list item 3
809000127All 8 models1
Casing door spring
Spare parts list item 4
809000075All 8 models1
Controls gasket
Spare parts list item 5
809000076All 8 models1
Casing door
Spare parts list item 6
809000077All 8 models1
Wall bracket (also for Q85S, Q130S)
Spare parts list item 76
809000065All 8 models1
Quick release, small
Spare parts list item 87
809000078All 8 models1
Quick release, large
Spare parts list item 88
809000079All 8 models1

Other

PartPart #FitsQtySize / rating
Fitting kit, complete
Part number order inferred from column order in the kit table
804000088E50CRN1
Fitting kit, complete
Part number order inferred from column order in the kit table
804000046E75CRN, E75CRP1
Fitting kit, complete
Part number order inferred from column order in the kit table
804000047E110CRN, E110CRP1
Flow switch accessory
Needed to turn plate warming off
803000015E50CRN1
Low loss header plumbing kit
For zone pump systems or high system pressure drop
804000061All 8 models1
User manual
Spare parts list item 7
800000012All 8 models1
Installation manual
Spare parts list item 8
800000013All 8 models1
Screw Taptite M5x8809000022All 8 models3 per pack
Boiler tool kit809000024All 8 models1
Flue gas sensor plug809000040All 8 models1
Bolt M5x12 hex socket809000045All 8 models3 per pack
T-piece for T3 sensor807000048All 8 models1
Bolt M6x20 stainless809000089All 8 models3 per pack
Pump gasket809000056All 8 models2 per pack
Pump UPER 20-58, 120 V807000126E50CRN, E75CRN, E75CRP1
Pump UPER 20-78, 120 V807000127E110CRN, E110CRP1
NTC sensor T2/T3805000032All 8 models1
Water pressure sensor805000034All 8 models1
Water pressure sensor cable805000050All 8 models1
NTC sensor T1/T3805000035All 8 models1
Outdoor reset sensor ARV12805000047All 8 models1
Side mounting kit for low loss header
Appendix B.2
804000071E50CR, E75CR, E110CR1
PVC FGV concentric kit
Third-party vent product listed as approved: IPEX
196006All 8 models1
PVC FGV wall termination kit
Third-party vent product listed as approved: IPEX
81219All 8 models1
CPVC FGV concentric vent kit
Third-party vent product listed as approved: IPEX
197009All 8 models1
Wall kit with cap
Third-party vent product listed as approved: Simpson Dura-Vent
FSSCWMK35All 8 models1
Roof kit with cap
Third-party vent product listed as approved: Simpson Dura-Vent
FSSCTRK35All 8 models1
2 in. (60 mm) concentric horizontal termination kit
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-HKAll 8 models1
2 in. (60 mm) concentric vertical termination cap kit
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-VKAll 8 models1
2 in. (60 mm) flex chimney lining kit
Third-party vent product listed as approved: DuraVent PolyPro
2PPS-FKAll 8 models1
3 in. (80 mm) concentric horizontal termination kit
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-HKAll 8 models1
3 in. (80 mm) concentric vertical termination cap kit
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-VKAll 8 models1
3 in. (80 mm) flex chimney lining kit
Third-party vent product listed as approved: DuraVent PolyPro
3PPS-FKAll 8 models1
4 in. (100 mm) concentric horizontal termination kit
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-HKAll 8 models1
4 in. (100 mm) concentric vertical termination cap kit
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-VKAll 8 models1
4 in. (100 mm) flex chimney lining kit
Third-party vent product listed as approved: DuraVent PolyPro
4PPS-FKAll 8 models1
Raised horizontal termination snorkel kit
Third-party vent product listed as approved: Rinnai/Ubbink
224047PPAll 8 models1

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116) (pages 9, 18, 20, 25, 26, 67, 80, 82, 84, 86, 93). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.