Navien · Furnace · NPF series

NPF700-100U&H&D (NG) parts

69 replacement parts that fit the Navien NPF700-100U&H&D (NG), with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Heat Exchanger Bracket20054459A1
Condensate Drain Pan30031098A1
Exhaust duct30031100A1
Mix Chamber30031427A1
Backup ring
Replaces / alternate: Service code 20021730*.
20021730B1
O-Ring (Φ18.8×Φ2.4)
Replaces / alternate: Service code 20027347*.
20027347A1Φ18.8×Φ2.4
Heat Exchanger Connection Adapter30028083A1
Fastener (H)
Replaces / alternate: Service code 20007878*.
20007878A1
Sight Glass
Replaces / alternate: Service code 30033873*.
30031934A1
Flame Rod & Ignitor Gasket
Replaces / alternate: Service code 20051913*.
20049482A1
Flame Rod & Ignitor
Replaces / alternate: Service code 30033141*.
30031546A1
Heat Exchanger Cover20054294A1
Bolt M4×18L×Φ12
Replaces / alternate: Service code 20023655*.
20023655A1M4×18L×Φ12
Screw D4 x 8L
Replaces / alternate: Service code 20006536*.
20006536A1D4 x 8L
Screw M4 X 10, B TYPE
Replaces / alternate: Service code 20038753*.
20038753A1M4 X 10
Burner Fuse Bracket20050642A1
Burner Fuse
Replaces / alternate: Service code 30032156*.
30032156A1
Damper
Replaces / alternate: Service code 30032692*.
30032692A1
Heat Exchanger outlet Adapter
Replaces / alternate: Service code 30031101*.
30031101A1
Pressure transmission pipe
Replaces / alternate: Service code 30031967*.
30031967A1
Pressure transmission pipe
Replaces / alternate: Service code 30031382*.
30031382A1
Hot water Joint Pipe
Replaces / alternate: Service code 30041646*.
30041646A1
Thermistor (Exhaust)
Replaces / alternate: Service code 30009478*.
30009478A1
High Limit Switch
Replaces / alternate: Service code 30002577*.
30002577A1
Flow Sensor
Replaces / alternate: Service code 30031591*.
30031591A1
Ignition Transformer
Replaces / alternate: Service code 30026063*.
30026063A1
Thermistor (Blue)
Replaces / alternate: Service code 30008366*.
30008366A1
Exhaust Test Port Cover
Replaces / alternate: Service code 30033933*.
30033933A1
Bolt (M4x08L)
Model applicability not listed in table Replaces / alternate: Service code 20006377*.
20006377A1M4x08L
Water Drain Pan
No service code listed
20060578A1
Strainer
Model applicability not listed in table Replaces / alternate: Service code 30031107*.
30031107A1
O-ring (P28)
Used at items 4 and 7 Replaces / alternate: Service code 20062030*.
20062030A1P28
O-ring (P20)
Replaces / alternate: Service code 20017212*.
20017212A1P20
Circulation Pump
Model applicability not listed in table Replaces / alternate: Service code 30030560*.
30030560A1
Fastener (D29)
Replaces / alternate: Service code 20059770*.
20059770A1D29
Leak Detector
Replaces / alternate: Service code 30031685*.
30031685A1
Screw (S10A, M3x6L)
No service code listed
20024374A1M3x6L
Water Tank
Replaces / alternate: Service code 30031105*.
30031105A1
Air Release Cap
No service code listed
20013352B1
Water Fill Cap
Replaces / alternate: Service code 20060755*.
20060755A1
O-ring (P18)
Replaces / alternate: Service code 20006954*.
20006954A1P18
Fastener (18)
Replaces / alternate: Service code 20045992*.
20045992A118
Overflow Cap
Replaces / alternate: Service code 20060844*.
20060844A1
Pump Bracket
No service code listed
20060578B1
Water Flow Adjust Valve
Replaces / alternate: Service code 30041144*.
30041144A1
Water Coil Drain Cock
Replaces / alternate: Service code 20081700*.
20081700A1
Water Coil Drain Adapter
Replaces / alternate: Service code 20081699*.
20081699A1
O-ring (G70)
Replaces / alternate: Service code 20007001*.
20007001A1G70
Silencer Adapter
No service code listed
20054544A1
Silencer
Replaces / alternate: Service code 30027844*.
30027844A1
Orifice Gasket (Inner)
Replaces / alternate: Service code 20054478*.
20054478A1
Orifice (NG)20060816A1Natural gas
Screw (M3x5)
Replaces / alternate: Service code 20006365*.
20006365A1M3x5
Orifice Gasket (Outer)
Replaces / alternate: Service code 20054479*.
20054479A1
Bolt (M4x12)
Listed at items 12 and 17 Replaces / alternate: Service code 20006390*.
20006390A2M4x12
Gas Valve
Replaces / alternate: Service code 30011586*.
30011586B1
Gas Connection Adapter
Replaces / alternate: Service code 20018430*.
20018430A1
Gas Valve Inlet Gasket
No service code listed
20058408A1
Gas Inlet Adapter Gasket
Replaces / alternate: Service code 20023581*.
20023581A1
O-ring (P20)
Replaces / alternate: Service code 20006934*.
20006934A1P20
Motor Bracket
No service code listed
20061476A1
Motor Bracket Band
Replaces / alternate: Service code 30033144*.
20061477A1
Washer (Motor Band)
Replaces / alternate: Service code 30033144*.
20061582A1
Washer Based Nut (S17C, M8)
Replaces / alternate: Service code 30033144*.
20061585A1M8
Hexagon Bolt (S10A, M8x45)20061583A1M8x45
Pad (Hardness 40)
Replaces / alternate: Service code 30033150*.
20061577A1Hardness 40
Washer (Pad)20061580A1
Flanged Hexagon Bolt (S10A, M8x40L)20061586A1M8x40L
Bushing (Φ11.8x17)
Replaces / alternate: Service code 30033150*.
20063621A1Φ11.8x17

Source: Navien NPF installation and operation manual, p. 176 (pages 168, 176, 178, 180). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.