Goodman · Heat pump · GSZH5 series
GSZH504210AA parts
33 replacement parts that fit the Goodman GSZH504210AA, with OEM part numbers, grouped by system.
Controls & boards
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Defrost control board | PCBDM133 | 1 | |
| Defrost control sensor | 0130M00723 | 1 |
Pressure & limit switches
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| High pressure switch | 0130M00089 | 1 | |
| Low pressure switch | 0130M00088 | 1 |
Electrical
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Contactor, 1 pole | CONT1P030024V | 1 | 30 A, 24 V coil |
| Run capacitor, dual round | CAB050450440CT | 1 | 5/45 µF, 440 V |
| Capacitor strap | 4400065 | 1 | |
| Compressor harness | 0159R00002P | 1 | 46 in. |
| Reversing valve harness | 0130M00410 | 1 | |
| Crankcase heater | 0163R00007 | 1 | 230 V, 40 W |
| Crankcase heater thermostat | 0130M00106 | 1 | |
| Disc thermostat | 0130M00349 | 1 |
Motors & blowers
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Condenser fan motor | 0131M00807 | 1 | 1/4 HP, 1 speed, 8 pole |
| Condenser fan blade | 0150M00066 | 1 | 26 in. |
Refrigerant circuit
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Compressor, scroll | ZP34K7EPFV130 | 1 | 208/230 V 1 ph |
| Compressor grommet | B1339533 | 4 | |
| TXV, adjustable, R-410A | 0151R00217 | 1 | |
| Reversing valve | 0151R00071 | 1 | |
| Reversing valve solenoid coil | B1225022 | 1 | |
| Service valve, liquid | 0151R00187 | 1 | 3/8 in. |
| Service valve, suction | 0151R00186 | 1 | 7/8 in. |
| Suction accumulator | B1226207 | 1 | |
| Filter drier, bi-flow | 0162R00056 | 1 | |
| Muffler | 0162R00007 | 1 | 1/2 x 1/2 in. |
| Charge compensator | 0151R00229 | 1 | |
| Valve core | B1787000 | 1 | |
| Outdoor coil with tubing | 0201R00759 | 1 |
Cabinet & doors
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Fan grille | 0152R00026 | 1 | 35 in. cabinet |
| Fan venturi | 0161R00105 | 1 | 35 in. cabinet |
| Top panel, painted | 0121R00936PDG | 1 | 35 in. cabinet |
| Control cover | 0121R00937PDG | 1 | |
| Base pan | 0121R00007PDG | 1 | 35 in. cabinet |
| Nameplate | 0161R00092 | 1 |
Same series
The GSZH5 parts list shows every part for all 7 models side by side. Other models: GSZH501810AA, GSZH502410AA, GSZH503010AA, GSZH503610AA, GSZH504810AA, GSZH506010AA.
Source: Goodman repair parts manual RP-G4326 (June 2022) (pages 3, 5, 7, 9). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.