Goodman / Amana · Furnace parts
Goodman GMVC95 and Amana AMVC95 95% variable-speed furnace: parts list
99 replacement parts with OEM part numbers for 30 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Controls & boards · Ignition & flame · Gas valve & orifices · Pressure & limit switches · Electrical · Motors & blowers · Inducer & venting · Heat exchanger & burners · Condensate · Cabinet & doors
Controls & boards
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Integrated furnace control board | PCBKF103 | All 30 models | 1 | |
| Model memory chip for control board | 0130F00135 | AMVC950453BXAC | 1 | |
| Model memory chip for control board | 0130F00090 | AMVC950453BXAD, GMVC950453BXAD | 1 | |
| Model memory chip for control board | 0130F00272 | AMVC950453BXAE | 1 | |
| Model memory chip for control board | 0130F00136 | AMVC950704CXAC | 1 | |
| Model memory chip for control board | 0130F00121 | AMVC950704CXAD, GMVC950704CXAD | 1 | |
| Model memory chip for control board | 0130F00273 | AMVC950704CXAE | 1 | |
| Model memory chip for control board | 0130F00190 | AMVC950905CXAB, GMVC950905CXAB, GMVC950905CXAC | 1 | |
| Model memory chip for control board | 0130F00182 | AMVC950905CXAC | 1 | |
| Model memory chip for control board | 0130F00274 | AMVC950905CXAD | 1 | |
| Model memory chip for control board | 0130F00138 | AMVC950905DXAC | 1 | |
| Model memory chip for control board | 0130F00122 | AMVC950905DXAD, GMVC950905DXAD | 1 | |
| Model memory chip for control board | 0130F00275 | AMVC950905DXAE | 1 | |
| Model memory chip for control board | 0130F00139 | AMVC951155DXAC | 1 | |
| Model memory chip for control board | 0130F00103 | AMVC951155DXAD | 1 | |
| Model memory chip for control board | 0130F00276 | AMVC951155DXAE | 1 | |
| Model memory chip for control board | 0130F00125 | GMVC950453BXAC | 1 | |
| Model memory chip for control board | 0130F00280 | GMVC950453BXAE | 1 | |
| Model memory chip for control board | 0130F00126 | GMVC950704CXAC | 1 | |
| Model memory chip for control board | 0130F00281 | GMVC950704CXAE | 1 | |
| Model memory chip for control board | 0130F00282 | GMVC950905CXAD | 1 | |
| Model memory chip for control board | 0130F00128 | GMVC950905DXAC | 1 | |
| Model memory chip for control board | 0130F00283 | GMVC950905DXAE | 1 | |
| Model memory chip for control board | 0130F00129 | GMVC951155DXAC | 1 | |
| Model memory chip for control board | 0130F00192 | GMVC951155DXAD | 1 | |
| Model memory chip for control board | 0130F00284 | GMVC951155DXAE | 1 |
Ignition & flame
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Hot surface igniter, silicon nitride | 0130F00008 | All 30 models | 1 | 17 second |
| Flame sensor | 0130F00010 | All 30 models | 1 |
Gas valve & orifices
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Gas valve | 0151M00028 | All 30 models | 1 | Honeywell VR92 |
| Burner orifice | 10716003 | All 30 models | As required | |
| Gas manifold, 2 burner | 20196401 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | |
| Gas manifold, 3 burner | 20196402 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | |
| Gas manifold, 4 burner | 20196403 | 12 models: AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE | 1 | |
| Gas manifold, 5 burner | 20196404 | AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 |
Pressure & limit switches
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Pressure switch (yellow) | 20197308 | All 30 models | 1 | |
| Pressure switch (gray) | 11177113 | 12 models: AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | |
| Pressure switch | 0130F00251 | AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD | 1 | |
| Pressure switch (olive) | 11177114 | 12 models: AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | |
| Pressure switch hose | 0164M00011 | AMVC950453BXAC, GMVC950453BXAC | 1 | |
| Pressure switch hose | 0164M00012 | AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAD, GMVC950453BXAE | 1 | |
| Pressure switch hose | 0164M00013 | AMVC950905CXAC, AMVC950905CXAD | 1 | |
| Pressure switch hose | 0164M00015 | AMVC951155DXAC | 1 | |
| Primary limit switch (yellow) | 20162905 | 12 models: AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE | 1 | |
| Primary limit switch | 20162907 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | |
| Primary limit switch Goodman service bulletin SF-054r1 applies to this part | 20162904 | AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | |
| Flame rollout switch, manual reset | 10123518 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | |
| Flame rollout switch, manual reset (gray) | 10123537 | AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE | 1 | |
| Flame rollout switch, manual reset (yellow) | 10123533 | 18 models: AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | |
| Auxiliary limit, manual reset (red) | 10123535 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | |
| Auxiliary limit, manual reset (gray) | 10123537 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | |
| Auxiliary limit, manual reset | 10123536 | 12 models: AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE | 1 | 180 °F |
| Auxiliary limit, manual reset (yellow) | 10123533 | AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 |
Electrical
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Transformer | B1141605 | All 30 models | 1 | 120 V to 24 V, 40 VA |
| Line inductor (choke) for blower motor | B1141666 | 24 models: AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | 5.9 A |
| Door interlock switch | B1370818 | All 30 models | 1 | |
| Blower wire harness | 0259F00024 | All 30 models | 1 | |
| Control harness | 0259F00040 | All 30 models | 1 | |
| Power harness, line voltage | 0259F00041 | All 30 models | 1 | |
| Adapter wire harness | 0259M00004 | 10 models: AMVC950453BXAC, AMVC950704CXAC, AMVC950905CXAB, AMVC950905DXAC, AMVC951155DXAC, GMVC950453BXAC, GMVC950704CXAC, GMVC950905CXAB, GMVC950905DXAC, GMVC951155DXAC | 1 |
Motors & blowers
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Blower motor, ECM | 0131M00270 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | 1/2 HP |
| Blower motor, ECM | 0131M00271 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | 3/4 HP |
| Blower motor, ECM | 0131M00272 | 18 models: AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | 1 HP |
| Blower motor end bells | 0131M00182 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | 1/2 HP |
| Blower motor end bells | 0131M00183 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | 3/4 HP |
| Blower motor end bells | 0131M00184 | 18 models: AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | 1 HP |
| Blower wheel | B1368016 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | 10 x 8 in. |
| Blower wheel | B1368047 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | 10 x 10 in. |
| Blower wheel | D6723311 | 18 models: AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | |
| Blower housing | 0271F00074 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | 10 x 8 in. |
| Blower housing | 0271F00004P | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | 10 x 10 in. |
| Blower housing | 0271F00047 | 18 models: AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | 11 x 10 in. |
| Blower motor grommet | A4002702 | All 30 models | 1 |
Inducer & venting
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Inducer (draft) blower assembly | 0271F00126 | All 30 models | 1 | |
| Inducer blower shield | 11165107 | All 30 models | 1 | |
| Flue pipe | 22309501 | All 30 models | 1 | |
| Flue elbow | 20171802 | All 30 models | 1 | |
| Fresh air coupling | 20049701 | All 30 models | 1 |
Heat exchanger & burners
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Heat exchanger assembly, 2 burner | 0257F00143 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | |
| Heat exchanger assembly, 3 burner | 0257F00146 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE | 1 | |
| Heat exchanger assembly, 3 burner | 0257F00139 | GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | |
| Heat exchanger assembly | 0257F00205 | AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD | 1 | |
| Heat exchanger assembly | 0257F00206 | GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD | 1 | |
| Heat exchanger assembly, 4 burner | 0257F00140 | AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE | 1 | |
| Heat exchanger assembly, 5 burner | 0257F00174 | AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE | 1 | |
| Heat exchanger assembly, 5 burner | 0257F00180 | GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 | |
| Inshot burner | 10735102 | All 30 models | As required | |
| Burner bracket, 2 burner | 20190410 | AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE | 1 | |
| Burner bracket, 3 burner | 20190411 | AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE | 1 | |
| Burner bracket, 4 burner | 20190412 | 12 models: AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE | 1 | |
| Burner bracket, 5 burner | 20190413 | AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 |
Condensate
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Drain trap | 20171701 | All 30 models | 1 | |
| Drain hose | 20201901 | All 30 models | 1 | |
| Drain hose | 20201902 | All 30 models | 1 | |
| Drain tube | 20201802 | All 30 models | 2 | |
| Rubber coupling | 10254303 | All 30 models | 1 | |
| Standpipe kit | 10195517 | All 30 models | 1 |
Cabinet & doors
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Control mounting panel | 0121F00094 | All 30 models | 1 | |
| Amana nameplate | 0161M00003P | 15 models: AMVC950453BXAC, AMVC950453BXAD, AMVC950453BXAE, AMVC950704CXAC, AMVC950704CXAD, AMVC950704CXAE, AMVC950905CXAB, AMVC950905CXAC, AMVC950905CXAD, AMVC950905DXAC, AMVC950905DXAD, AMVC950905DXAE, AMVC951155DXAC, AMVC951155DXAD, AMVC951155DXAE | 1 | |
| Goodman nameplate | 0161F00000P | 15 models: GMVC950453BXAC, GMVC950453BXAD, GMVC950453BXAE, GMVC950704CXAC, GMVC950704CXAD, GMVC950704CXAE, GMVC950905CXAB, GMVC950905CXAC, GMVC950905CXAD, GMVC950905DXAC, GMVC950905DXAD, GMVC950905DXAE, GMVC951155DXAC, GMVC951155DXAD, GMVC951155DXAE | 1 |
Source: Goodman repair parts manual RP-719A (May 2014) (pages 3, 5, 7, 9, 11). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.