Goodman · Furnace · GC9C96 series

GC9C961005CNAA parts

87 replacement parts that fit the Goodman GC9C961005CNAA, with OEM part numbers, grouped by system.

Controls & boards

PartPart #QtySize / rating
Furnace control board
Counterflow model.
PCBBF1641
Control mounting plate
Counterflow model.
0121F004641

Ignition & flame

PartPart #QtySize / rating
Flame sensor
Counterflow model.
0130F000101
Igniter (silicon nitride, 17 sec)
Counterflow model.
0130F000081

Gas valve & orifices

PartPart #QtySize / rating
Gas valve
Counterflow model.
0151M000271
Orifice
Counterflow model.
107160052
Manifold
Counterflow model.
0163F000101
Orifice bracket, 5 burner
Counterflow model.
0121F004661

Pressure & limit switches

PartPart #QtySize / rating
Auxiliary limit, light blue, 120 F
Counterflow model.
0130F000382
Manual reset rollout limit
Counterflow model.
0130F001231
Pressure switch
Counterflow model.
0130F004291
Pressure switch
Counterflow model.
0130F004341
Primary limit, white
Counterflow model.
201629061
Door interlock switch
Counterflow model.
0130M002431
Pressure switch hose, 6 in.
Counterflow model.
0164M001151
Pressure switch hose, 8 in.
Counterflow model.
0164M001171
Primary limit heat shield
Counterflow model.
0121F004391

Electrical

PartPart #QtySize / rating
Transformer 120 V to 24 V
Counterflow model.
0130M00140140 VA
Motor harness
Counterflow model.
0159F001601
Blower harness
Counterflow model.
0259F000241
Wiring harness
Counterflow model.
0159F001411
Junction box
Counterflow model.
0161F000421
Junction box lid
Counterflow model.
0161F000431

Motors & blowers

PartPart #QtySize / rating
Blower assembly, 11 x 10
Counterflow model.
0271F005071
Blower motor without controller
Counterflow model.
0131F00114M11 HP
Blower motor, programmed
Counterflow model.
0131F002311
Motor mount band, heavy duty
Counterflow model.
0121M000391
Motor mount arm
Counterflow model.
0163M005383
Blower motor without controller
Counterflow model. Listed as a shaft-end replacement option; model fit not printed
0131F00113M13/4 HP

Inducer & venting

PartPart #QtySize / rating
Inducer motor
Counterflow model.
0171M000021
Flue elbow, 21 in. counterflow
Counterflow model.
0164F000041
Coupling
Counterflow model.
0161F000371
Inducer blower gasket
Counterflow model.
0154F000431

Heat exchanger & burners

PartPart #QtySize / rating
Burner (inshot)
Counterflow model.
0163F000172
Heat exchanger assembly
Counterflow model.
0257F004291
Heat exchanger insulation, 21 in.
Counterflow model.
0160F000161
Burner bracket, 5 burner
Counterflow model.
0121F004531
Front cover
Counterflow model.
0161F000721
Rear cover
Counterflow model.
0121F003181
Insulation retainer
Counterflow model.
0121F005841
Burner shield
Counterflow model.
0121F005421
Coil shield
Counterflow model.
0121F003552

Condensate

PartPart #QtySize / rating
Drain kit assembly
Counterflow model.
0270F054031
Drain trap
Counterflow model.
0161F000461
Drain tube assembly (counterflow)
Counterflow model.
0270F035151
Drain tube assembly (counterflow)
Counterflow model.
0270F031261
Straight pipe (counterflow)
Counterflow model.
0161F000642
Hose clamp
Counterflow model.
0163M004602

Cabinet & doors

PartPart #QtySize / rating
Goodman nameplate
Counterflow model.
0161F000861
Access door, 21 in.
Counterflow model.
0121F00292DG1
Blower door, 21 in.
Counterflow model.
0121F00289DG1
View port bushing
Counterflow model.
B13921392
Base pan, 21 in., counterflow
Counterflow model.
0121F00549DG1
Blower deck, 21 in.
Counterflow model.
0121F005371
Deck angle
Counterflow model.
0121F003151
Furnace top, 21 in., counterflow
Counterflow model.
0121F00434DG1
Side angle
Counterflow model.
0121F003132
Door switch bracket
Counterflow model.
0121F003891

Other

PartPart #QtySize / rating
Gasket
Counterflow model.
0154F000242
Gasket
Counterflow model.
0154F000252
Deck gasket
Counterflow model.
0154F000211
Pipe grommet
Counterflow model.
M05013011
Button plug
Counterflow model.
M05708081
Button plug
Counterflow model.
M05708061
Hole plug
Counterflow model.
0161M000271
Plastic plug, 1 in.
Counterflow model.
B13920214
Universal bushing
Counterflow model.
B13921041
Button plug
Counterflow model.
M03103452
Button plug
Counterflow model.
M05708071
Decorative screw
Counterflow model.
M02097303
Fresh-air gasket
Counterflow model.
0154F000411
Hex nut insert
Counterflow model.
0163M003193
Retainer screw
Counterflow model.
M02739043
Thread-cutting screw, 1.25 in.
Counterflow model.
M02505653
Hex head all-thread tap bolt
Counterflow model.
0163M003201
Flat washer
Counterflow model.
B13929183
Locknut, nylon insert, 1/4-20
Counterflow model.
B13938001
Keps nut
Counterflow model.
M02820151
Machine screw
Counterflow model.
M02671441
Split lock washer
Counterflow model.
B13928201
Gasket
Counterflow model.
201793101
Tube plug
Counterflow model.
M03268041
Gasket
Counterflow model.
0154F000152
Gasket
Counterflow model.
0154F000161
Front cover gasket
Counterflow model.
0154F000301
Vinyl cap, 0.5 in.
Counterflow model.
A17811051
Rear cover gasket
Counterflow model.
0154F000381

Source: Goodman GC9C 96% EEM Counter Flow Furnace Repair Parts RP-G2340A. Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.