Goodman GC9C96 96% counterflow furnace: parts list

134 replacement parts with OEM part numbers for 14 models. Pick your model for a list of only the parts that fit it.

Jump to: Controls & boards · Ignition & flame · Gas valve & orifices · Pressure & limit switches · Electrical · Motors & blowers · Inducer & venting · Heat exchanger & burners · Condensate · Cabinet & doors · Other

Controls & boards

PartPart #FitsQtySize / rating
Two-stage integrated furnace control
Counterflow model.
PCBBF167GC9C960403BNAB, GC9C960603BNAB, GC9C960803BNAB, GC9C961005CNAB1
Furnace control board
Counterflow model.
PCBBF164GC9C960403BNAA, GC9C960603BNAA, GC9C960803BNAA, GC9C961005CNAA1
Control mounting plate
Counterflow model.
0121F00464All 14 models1

Ignition & flame

PartPart #FitsQtySize / rating
Flame sensor
Counterflow model.
0130F00010All 14 models1
Igniter (silicon nitride, 17 sec)
Counterflow model.
0130F00008All 14 models1

Gas valve & orifices

PartPart #FitsQtySize / rating
Gas valve
Counterflow model.
0151M00027All 14 models1
Orifice
Counterflow model.
10716005All 14 models2
Manifold
Counterflow model.
0163F00007GC9C960403BNAA, GC9C960403BNAB1
Manifold
Counterflow model.
0163F00008GC9C960603BNAA, GC9C960603BNAB1
Manifold
Counterflow model.
0163F00010GC9C961005CNAA, GC9C961005CNAB1
Manifold
Counterflow model.
0163F00014GC9C960803BNAA, GC9C960803BNAB1
Orifice bracket, 2 burner
Counterflow model.
0121F00469GC9C960403BNAA, GC9C960403BNAB1
Orifice bracket, 3 burner
Counterflow model.
0121F00468GC9C960603BNAA, GC9C960603BNAB1
Orifice bracket, 4 burner
Counterflow model.
0121F00467GC9C960803BNAA, GC9C960803BNAB1
Orifice bracket, 5 burner
Counterflow model.
0121F00466GC9C961005CNAA, GC9C961005CNAB1

Pressure & limit switches

PartPart #FitsQtySize / rating
Primary limit, temperature control
Counterflow model. Manual flags it with an asterisk; the service bulletin it points to is not named here
20162904GC9C960803BNAA, GC9C960803BNAB1
Auxiliary limit, light blue, 120 F
Counterflow model.
0130F00038All 14 models2
Manual reset rollout limit
Counterflow model.
10123538GC9C960603BNAA, GC9C960603BNAB1
Manual reset rollout limit
Counterflow model.
10123533GC9C960403BNAA, GC9C960403BNAB, GC9C960803BNAA, GC9C960803BNAB1
Manual reset rollout limit
Counterflow model.
0130F00123GC9C961005CNAA, GC9C961005CNAB1
Pressure switch
Counterflow model.
0130F00429All 14 models1
Pressure switch
Counterflow model.
0130F00434GC9C961005CNAA, GC9C961005CNAB1
Pressure switch
Counterflow model.
0130F00435GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB1
Pressure switch
Counterflow model.
0130F00436GC9C960803BNAA, GC9C960803BNAB1
Primary limit, white
Counterflow model.
20162906GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C961005CNAA, GC9C961005CNAB1
Door interlock switch
Counterflow model.
0130M00243All 14 models1
Pressure switch hose, 6 in.
Counterflow model.
0164M00115All 14 models1
Pressure switch hose, 8 in.
Counterflow model.
0164M00117GC9C961005CNAA, GC9C961005CNAB1
Primary limit heat shield
Counterflow model.
0121F00439All 14 models1

Electrical

PartPart #FitsQtySize / rating
Transformer 120 V to 24 V
Counterflow model.
0130M00140All 14 models140 VA
Motor harness
Counterflow model.
0159F00160All 14 models1
Blower harness
Counterflow model.
0259F00024All 14 models1
Wiring harness
Counterflow model.
0159F00140GC9C960403BNAA, GC9C960403BNAB1
Wiring harness
Counterflow model.
0159F00141GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB, GC9C961005CNAA, GC9C961005CNAB1
Junction box
Counterflow model.
0161F00042All 14 models1
Junction box lid
Counterflow model.
0161F00043All 14 models1

Motors & blowers

PartPart #FitsQtySize / rating
Blower housing assembly
Counterflow model.
0271F00462GC9C960403BNAA, GC9C960403BNAB1
Blower block-off, 10 x 8
Counterflow model.
764740GC9C960403BNAA, GC9C960403BNAB1
Blower assembly, 11 x 10
Counterflow model.
0271F00507GC9C961005CNAA, GC9C961005CNAB1
Blower assembly, 11 x 8
Counterflow model.
0271F00506GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Blower motor without controller
Counterflow model.
0131F00114MGC9C961005CNAA, GC9C961005CNAB11 HP
Blower motor without controller
Counterflow model.
0131F00112MGC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB11/2 HP
Blower motor, programmed
Counterflow model.
0131F00229GC9C960603BNAA, GC9C960603BNAB1
Blower motor, programmed
Counterflow model.
0131F00228GC9C960403BNAA, GC9C960403BNAB1
Blower motor, programmed
Counterflow model.
0131F00231GC9C961005CNAA, GC9C961005CNAB1
Blower motor, programmed
Counterflow model.
0131F00230GC9C960803BNAA, GC9C960803BNAB1
Blower wheel, 10 x 8
Counterflow model.
0150M00043GC9C960403BNAA, GC9C960403BNAB1
Motor mount band, heavy duty
Counterflow model.
0121M00039All 14 models1
Motor mount arm
Counterflow model.
0163M00538All 14 models3
Blower motor without controller
Counterflow model. Listed as a shaft-end replacement option; model fit not printed
0131F00113MAll 14 models13/4 HP

Inducer & venting

PartPart #FitsQtySize / rating
Inducer motor
Counterflow model.
0171M00002All 14 models1
Flue elbow, 17.5 in. counterflow
Counterflow model.
0164F00003GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Flue elbow, 21 in. counterflow
Counterflow model.
0164F00004GC9C961005CNAA, GC9C961005CNAB1
Coupling
Counterflow model.
0161F00037All 14 models1
Inducer blower gasket
Counterflow model.
0154F00043All 14 models1

Heat exchanger & burners

PartPart #FitsQtySize / rating
Burner (inshot)
Counterflow model.
0163F00017All 14 models2
Heat exchanger assembly
Counterflow model.
0257F00429GC9C961005CNAA, GC9C961005CNAB1
Heat exchanger assembly
Counterflow model.
0257F00421GC9C960803BNAA, GC9C960803BNAB1
Heat exchanger assembly
Counterflow model.
0257F00420GC9C960603BNAA, GC9C960603BNAB1
Heat exchanger assembly
Counterflow model.
0257F00419GC9C960403BNAA, GC9C960403BNAB1
Heat exchanger insulation, 17.5 in.
Counterflow model.
0160F00015GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Heat exchanger insulation, 21 in.
Counterflow model.
0160F00016GC9C961005CNAA, GC9C961005CNAB1
Burner bracket, 2 burner
Counterflow model.
0121F00456GC9C960403BNAA, GC9C960403BNAB1
Burner bracket, 3 burner
Counterflow model.
0121F00455GC9C960603BNAA, GC9C960603BNAB1
Burner bracket, 4 burner
Counterflow model.
0121F00454GC9C960803BNAA, GC9C960803BNAB1
Burner bracket, 5 burner
Counterflow model.
0121F00453GC9C961005CNAA, GC9C961005CNAB1
Front cover
Counterflow model.
0161F00053GC9C960403BNAA, GC9C960403BNAB1
Front cover
Counterflow model.
0161F00072GC9C961005CNAA, GC9C961005CNAB1
Front cover
Counterflow model.
0161F00078GC9C960603BNAA, GC9C960603BNAB1
Front cover
Counterflow model.
0161F00079GC9C960803BNAA, GC9C960803BNAB1
Rear cover
Counterflow model.
0121F00317GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Rear cover
Counterflow model.
0121F00318GC9C961005CNAA, GC9C961005CNAB1
Insulation retainer
Counterflow model.
0121F00583GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Insulation retainer
Counterflow model.
0121F00584GC9C961005CNAA, GC9C961005CNAB1
Burner shield
Counterflow model.
0121F00542GC9C961005CNAA, GC9C961005CNAB1
Coil shield
Counterflow model.
0121F00355All 14 models2

Condensate

PartPart #FitsQtySize / rating
Drain kit assembly
Counterflow model.
0270F05403All 14 models1
Drain trap
Counterflow model.
0161F00046All 14 models1
Drain tube assembly (counterflow)
Counterflow model.
0270F03125GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Drain tube assembly (counterflow)
Counterflow model.
0270F03515GC9C961005CNAA, GC9C961005CNAB1
Drain tube assembly (counterflow)
Counterflow model.
0270F03126GC9C961005CNAA, GC9C961005CNAB1
Drain tube assembly (counterflow)
Counterflow model.
0270F03514GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Straight pipe (counterflow)
Counterflow model.
0161F00064All 14 models2
Hose clamp
Counterflow model.
0163M00460All 14 models2

Cabinet & doors

PartPart #FitsQtySize / rating
Goodman nameplate
Counterflow model.
0161F00086All 14 models1
Access door, 17.5 in.
Counterflow model.
0121F00291DGGC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Access door, 21 in.
Counterflow model.
0121F00292DGGC9C961005CNAA, GC9C961005CNAB1
Blower door, 17.5 in.
Counterflow model.
0121F00288DGGC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Blower door, 21 in.
Counterflow model.
0121F00289DGGC9C961005CNAA, GC9C961005CNAB1
View port bushing
Counterflow model.
B1392139All 14 models2
Base pan, 17.5 in., counterflow
Counterflow model.
0121F00548DGGC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Base pan, 21 in., counterflow
Counterflow model.
0121F00549DGGC9C961005CNAA, GC9C961005CNAB1
Blower deck, 17.5 in.
Counterflow model.
0121F00536GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Blower deck, 21 in.
Counterflow model.
0121F00537GC9C961005CNAA, GC9C961005CNAB1
Deck angle
Counterflow model.
0121F00314GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Deck angle
Counterflow model.
0121F00315GC9C961005CNAA, GC9C961005CNAB1
Furnace top, 17.5 in., counterflow
Counterflow model.
0121F00426DGGC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Furnace top, 21 in., counterflow
Counterflow model.
0121F00434DGGC9C961005CNAA, GC9C961005CNAB1
Side angle
Counterflow model.
0121F00313All 14 models2
Door switch bracket
Counterflow model.
0121F00389All 14 models1

Other

PartPart #FitsQtySize / rating
Gasket
Counterflow model.
0154F00024All 14 models2
Gasket
Counterflow model.
0154F00025All 14 models2
Deck gasket
Counterflow model.
0154F00020GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Deck gasket
Counterflow model.
0154F00021GC9C961005CNAA, GC9C961005CNAB1
Pipe grommet
Counterflow model.
M0501301All 14 models1
Button plug
Counterflow model.
M0570808All 14 models1
Button plug
Counterflow model.
M0570806All 14 models1
Hole plug
Counterflow model.
0161M00027All 14 models1
Plastic plug, 1 in.
Counterflow model.
B1392021All 14 models4
Universal bushing
Counterflow model.
B1392104All 14 models1
Button plug
Counterflow model.
M0310345All 14 models2
Button plug
Counterflow model.
M0570807All 14 models1
Decorative screw
Counterflow model.
M0209730All 14 models3
Fresh-air gasket
Counterflow model.
0154F00041All 14 models1
Hex nut insert
Counterflow model.
0163M00319All 14 models3
Retainer screw
Counterflow model.
M0273904All 14 models3
Thread-cutting screw, 1.25 in.
Counterflow model.
M0250565All 14 models3
Hex head all-thread tap bolt
Counterflow model.
0163M00320All 14 models1
Flat washer
Counterflow model.
B1392918All 14 models3
Locknut, nylon insert, 1/4-20
Counterflow model.
B1393800All 14 models1
Keps nut
Counterflow model.
M0282015GC9C961005CNAA, GC9C961005CNAB1
Machine screw
Counterflow model.
M0267144GC9C961005CNAA, GC9C961005CNAB1
Split lock washer
Counterflow model.
B1392820GC9C961005CNAA, GC9C961005CNAB1
Gasket
Counterflow model.
20179309GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Gasket
Counterflow model.
20179310GC9C961005CNAA, GC9C961005CNAB1
Tube plug
Counterflow model.
M0326804All 14 models1
Gasket
Counterflow model.
0154F00015All 14 models2
Gasket
Counterflow model.
0154F00014GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Gasket
Counterflow model.
0154F00016GC9C961005CNAA, GC9C961005CNAB1
Front cover gasket
Counterflow model.
0154F00026GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Front cover gasket
Counterflow model.
0154F00030GC9C961005CNAA, GC9C961005CNAB1
Vinyl cap, 0.5 in.
Counterflow model.
A1781105All 14 models1
Rear cover gasket
Counterflow model.
0154F00037GC9C960403BNAA, GC9C960403BNAB, GC9C960603BNAA, GC9C960603BNAB, GC9C960803BNAA, GC9C960803BNAB1
Rear cover gasket
Counterflow model.
0154F00038GC9C961005CNAA, GC9C961005CNAB1

Source: Goodman GC9C 96% EEM Counter Flow Furnace Repair Parts RP-G2340A. Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.