Daikin · General troubleshooting
Water tank cleaning and lid removal
What is going on
Clean the tank daily when humidifying. Do not remove the valve part.
Check in this order
- Clean the inside by shaking a small amount of water with the lid closed, then pour it out.
- Remove water scale with a soft cloth, brush or cotton swab in lukewarm water with dissolved citric acid.
- Push the valve from the bottom with a finger and check it moves smoothly. Wipe out any dust with a cotton swab.
- Fill the tank, wait about 30 seconds and check for leaks from the bottom.
- To remove the lid, push the tank cover to bend it, lift the back of the lid, and release the 2 hooks.
- To fit the lid, push the front (2 places), then push the back (2 places) to secure the hooks.
- Check the lid is fully attached. Do not fit the lid twisted, and make sure the rubber packing is in place.
Applies to: Water tank and lid
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU installation & operation manual, p. 26-27. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.