Water spilled on the floor
What is going on
Water leaks out of the unit onto the floor.
Likely causes
- Unit was tilted, so water in the tank or tray spilled out
- Water scale buildup on the humidifying filters causes leakage
- Float is stuck, causing leakage
- Dust caught in the water tank valve, so the valve does not close
- Water scale around the water tank valve, so the valve does not close
Check in this order
- Before moving the unit, turn off the power and empty the water tank and humidifying tray.
- Clean water scale off the humidifying filters (see p. 28-29).
- Clean the float if it is stuck (see p. 28).
- Clean dust out of the water tank valve (see p. 27).
- Clean water scale from the area around the water tank valve (see p. 27).
Applies to: MCKB70YSAU
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU installation & operation manual, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.