Daikin · General troubleshooting
Water spilled on floor
What is going on
Tilting the unit or water scale or a stuck float can cause leaks. Dust in the tank valve or scale around it can stop the valve from sealing.
Likely causes
- Unit tilted
- Water scale on humidifying filters
- Stuck float
- Dust or scale on water tank valve
Check in this order
- Before moving the unit, turn off the power and empty the water tank and humidifying tray.
- Clean water scale from the humidifying filters (p. 28, 29).
- Clean the float so it moves freely (p. 28).
- Clean dust and scale from the water tank valve and its area (p. 27).
Applies to: Water tank, humidifying tray
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU operation manual, p. 39. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.