Daikin · General troubleshooting
Step 4 System Optimization: error history and calibration
What is going on
System Optimization shows error history, which logs alerts with an error code. Alerts are shown in white when not critical and yellow when critical. Calibration is also done here and the status menu shows data for the selected equipment.
Check in this order
- Open error history and review logged alerts. White means not critical and yellow means critical.
- Put the thermostat in OFF mode before calibrating.
- Wait 30 minutes so the thermostat can equalize before calibration.
- Use the status menu to check data for the selected equipment.
Applies to: Daikin One+ thermostat, System Optimization step
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin One+ Installation & Commissioning (S21), p. 29. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.