Daikin · General troubleshooting

Soak and clean the humidifying filter unit

Humidifying Air Purifier

What is going on

Soak weekly for light cleaning. Use citric acid or lemon juice monthly, or when smell, dirt or scale appears.

Likely causes

  • Odour from air outlet
  • Reduced humidifying capacity
  • Water scale

Check in this order

  1. About every week soak in lukewarm water (about 40 C / 104 F or less) or room temperature water.
  2. About every month, or when odour or scale appears: soak in the same water with citric acid or lemon juice for about 2 hours, then rinse.
  3. Citric acid about 20 g (2 tablespoons) in 3 L of water. Lemon juice: 1/4 cup per 3 cups of water, 100% lemon juice with no pulp.
  4. If dirt remains, soak for an extra 1 hour in plain lukewarm water.
  5. If odour persists, soak 30 to 60 minutes in water with kitchen neutral detergent or baking soda (2 tablespoons per 1 L), then rinse.
  6. Scrub gently with a soft sponge. Do not use a brush, and do not detach the frame.
  7. Rinse thoroughly. Parts can go back in while still wet.

Applies to: Humidifying filter unit

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin MCKB70YSAU installation & operation manual, p. 29. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.