Daikin · General troubleshooting

Replace the humidifying filters

Humidifying Air Purifier

What is going on

Replace when dirt or stains cannot be removed or humidifying capacity drops. Keep the frame and axle for reuse.

Likely causes

  • Dirt or stains that do not clean off
  • Reduced humidifying capacity (water usage rate)

Check in this order

  1. Stop operation, unplug the unit and remove the water tank.
  2. Disengage the 6 hooks on the frame, remove the upper half and pull the axle from the lower half.
  3. Remove the old humidifying filters from each frame.
  4. Slide the new filters under the 6 filter retainers, aligning the 6 protrusions with the filter holes.
  5. Match the engraved pattern on the frame with the pattern on the filter. Filters have a front and back.
  6. Align the frame grooves with the axle notches, then engage the 6 hooks until a click is heard.

Applies to: Humidifying filters

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin MCKB70YSAU installation & operation manual, p. 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.