Daikin · General troubleshooting
Installing the carbon filter
What is going on
Remove the water tank, humidifying tray and filter fixing unit, fit the carbon filter onto the dust collection filter, then refit the parts in order.
Check in this order
- Take out the water tank by pressing the lever and releasing the side lock.
- Remove the humidifying tray by lifting it slightly and pulling it out.
- Slide the fixing tab to unlock the filter fixing unit, lift its grip and pull it out.
- Take the carbon filter out of its bag. It has no front or back. Wear gloves, and dispose of the bag and desiccant under local rules.
- Push the short side of the carbon filter fully into the unit and lay it on the dust collection filter. Turn it if it does not fit.
- Refit the filter fixing unit and slide the fixing tab to lock it.
- Refit the humidifying tray, then the water tank.
Applies to: Carbon filter (black), filter fixing unit
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU installation & operation manual, p. 13, p. 14, p. 15. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.