Clean the humidifying tray and float
What is going on
Wash about every 3 days, or sooner if odour or dirt is present. Do not remove the float.
Likely causes
- Water scale in tray
- Odour or dirt
Check in this order
- Wash the tray with water, using a soft cloth, brush or cotton swab in hard-to-reach places.
- Remove water scale with citric acid solution, lifting the float to check there is no scale under it.
- Rinse with water.
- Make sure the float is not stuck in scale, or water may leak.
- Pour water into the tray and check the float rises. Discard the water before refitting the tray.
- Removing the float stops humidifying operation.
Applies to: Humidifying tray and float
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU installation & operation manual, p. 28. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.