Daikin · General troubleshooting
Clean the dust/particle sensor
What is going on
Clean about once every 3 months. The sensor lens and air intake must be kept clear for accurate readings.
Check in this order
- Unplug the unit.
- Remove the pre-filter from the right side.
- Remove the cover of the sensor air intake by unhooking it and pulling toward you.
- Vacuum dust from the area with a crevice tool.
- Lightly rub the inside left side with a dry cotton swab, then vacuum again.
- Clean the lens area if dust is present.
- Refit the cover securely, otherwise a malfunction may result.
Applies to: Dust/particle sensor
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU installation & operation manual, p. 25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.