Carbon filter maintenance
What is going on
The carbon filter cannot be washed with water. Clean it dry, air it out for odour, and replace when the odour and dirt remain.
Likely causes
- Odour that remains after airing
- Dirt that cannot be vacuumed off
Check in this order
- Remove the water tank, humidifying tray and filter fixing unit to access the carbon filter.
- Hold the side of the carbon filter and remove it.
- Vacuum off dust. Do not rub the surface and do not wash it with water.
- If odour is present, expose it to airflow in a shaded place for about 1 day.
- If odour or dirt remain after cleaning, replace it. Wear gloves because the dust can soil hands.
- Replace the carbon filter at the same time as the dust collection filter when possible.
Applies to: Carbon filter
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU installation & operation manual, p. 26, 31. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.