Viessmann · Boiler
N/A 29 Open circuit at Multi terminal of power pump module
What the display is showing
Burner is in a hold/wait state and the boiler is not showing a fault. The open circuit is at terminals 1 and L on the Multi terminal of the power pump module.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
Good to know
- Open circuit at terminals 1 and L on Multi terminal of the power pump module.
What to do
- Check the connection at terminals 1 and L.
- Check the jumper or installed safety equipment on the Multi terminal of the power pump module.
Models that show this code
4 models in Vitodens 200-W B2HB
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Vitodens 200-W B2HB service instructions, p. 82. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.