Viessmann · Air handler

EH 0b Communication error between the two indoor chips

Medium severity Vitocal IND-A

What the control is telling you

The indoor PCB main chip is not receiving feedback from the other chip on the indoor board.

Applies to: DLFUAA indoor air handler (Vitocal IND-A)

Likely causes

  • Loose or faulty connection wires between the adapter board and the indoor main board
  • Faulty transfer (adapter) board
  • Faulty indoor main board

Test and repair steps

  1. Turn off the power, then turn it back on after 2 minutes.
  2. If the code still shows, check the connection wires between the adapter board and the main board, and reconnect them if loose.
  3. Retry. If the error still appears, replace the transfer board.
  4. If the system still does not run normally, replace the indoor main board.

Models that show this code

14 models in Vitocal IND-A

DLFLABH36XA3DLFLABH48XA3DLFLABH60XA3DLFSABH18XB3DLFSABH24XB3DLFSABH30XB3DLFSABH36XB3DLFUAAQ18XB3DLFUAAQ24XB3DLFUAAQ30XB3DLFUAAQ36XA3DLFUAAQ36XB3DLFUAAQ48XA3DLFUAAQ60XA3

Other codes on the same units

  • EL 16 Communication malfunction between adapter board and outdoor main board
  • FL 09 Indoor and outdoor unit mismatch

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: DLFUAA service manual, p. 32. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.