Rinnai · Wall furnace

73 Communication error

Medium severity EX DT

What the control is telling you

The manual lists this as a service-call fault: the the furnace's control components are not communicating.

Applies to: Rinnai EnergySaver direct vent wall furnaces EX08DT, EX11DT, EX17DT, EX22DT

Likely causes

  • Internal communication fault

Test and repair steps

  1. Turn the furnace off and back on with the ON/OFF button to try to clear the code.
  2. If the code stays or comes back on the next operation, a trained and qualified technician must service the unit.
  3. Technician inspect the part named in the code (communication error) and its connections, and repair or replace as needed.

Settings for these units

Clearances to combustibles and service · EX DT

LocationClearance
Top0 in. (0 mm)
Bottom / ground0 in. (0 mm)
Front (panel)40 in. (1 m) - flooring or carpet under 1.2 in. (30 mm) high not included
Back (including back spacer)0 in. (0 mm)
Sides (left and right)2 in. (50 mm)
Service access10 in. (254 mm) sides; 40 in. (1 m) front; area above per figure
Exhaust extension pipe1 in. (25.4 mm) to combustibles; 0 in. to non-combustibles

Rinnai recommends 10 in. (254 mm) at top and both sides for servicing.

Service clearance figure above the unit: 10 in. (254 mm) on EX08DT/EX11DT, 9 in. (229 mm) on EX17DT/EX22DT.

Models that show this code

5 models in EX DT

EX08DTEX11DTEX17DTEX22DTEX22DT-W

Other codes on the same units

  • 62 Convection fan fault
  • 70 ON/OFF or Set Back switch fault
  • 71 Solenoid valve failure
  • 72 Flame rod failure
  • 99 Flue blocked
  • A1-A8 / L1-L8 Gas code selection (gas type, altitude, vent length)
  • Economy Economy indicator lit
  • FILTER Filter lamp flashing red (air filter blocked)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai EX08DT/EX11DT and EX17DT/EX22DT Installation and Operation Manuals (200000083, 200000084), Table 9 'Diagnostic Codes', p.35–36. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.