Navien · Tankless water heater
Service/Installer menu Service / installer menu (Menu + Back)
What the display is showing
Hidden installer menu opened by holding the Menu and Back buttons together for 3 seconds. Contains 1. Installer Menu (including 1.2 Parameter Settings such as 1.2.14 Altitude Setting) and 2. Cascade Status and Set (3. Cascade System Setting, 4. Cascade System Removal).
Applies to: NPE-A2, NPE-S2
What to do
- Hold Menu and Back together for 3 seconds.
- Choose Installer Menu or Cascade Status and Set with OK.
- Press Back to leave.
Settings for these units
Installation clearances (indoor / outdoor) · Navien NPE-2
| Side | Indoor | Outdoor |
|---|---|---|
| Top | 9 in. (229 mm) | 36 in. (900 mm) |
| Back | 0.5 in. (13 mm) | 0.5 in. (13 mm) |
| Front | 4 in. (100 mm) | 24 in. (600 mm) |
| Sides | 3 in. (76 mm) | 3 in. (76 mm) |
| Bottom | 12 in. (300 mm) | 12 in. (300 mm) |
Vent clearance to combustibles is 0 in.
Outdoor: use the Navien Outdoor Vent Kit; keep 3 ft from an eave to the top of the vent terminals; mild climates only.
Water quality limits and flushing schedule · Navien NPE-2
| Hardness | grains/gal (mg/L) | Treatment | Flush frequency |
|---|---|---|---|
| Soft | 0-4 (0-60) | None | None |
| Moderately hard | 4-7 (61-120) | None required | Once a year |
| Hard | 7-9 (121-160) | Softener or Navien PeakFlow recommended | Once a year |
| Very hard | 9-12 (161-200) | Softener or PeakFlow highly recommended | Residential once a year; commercial twice a year |
| Extremely hard | >12 (200) | Softener or PeakFlow required | - |
Other max levels: hardness 200 mg/L, chloride 250, copper 1.0, iron 0.3, manganese 0.05, sulfate 250, TDS 500, zinc 5, chlorine 4 mg/L; aluminum 0.05-0.2 mg/L; pH 6.5-8.5.
Flushing is advised when no treatment device is installed; use white vinegar or a tankless descaler.
Models that show this code
7 models in Navien NPE-2
Other codes on the same units
- Recirculation/Space Heating Recirculation / space heating indicator
- Remote LED Remote controller LED colour
- Remote lock icon Remote lock mode on
- SL.xx Sub remote waiting for ID
- SUB Remote set as sub
- SYNC Remote synchronizing
- Start-up wizard First power-on start-up wizard
- Status/Flow Operation status and flow rate area
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NPE-A2/S2 Installation Manual, 3.8.2 and 5.2.1, p.61, 73. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.