Navien · Tankless water heater
Recirculation mode display Recirculation mode display
What the display is showing
Front-panel display of the selected recirculation mode.
Applies to: NPN-160U/180U/199U, NPN-120E/160E/180E/199E
Settings for these units
Installation clearances (indoor / outdoor) · Navien NPN
| Side | Indoor: combustibles | Indoor: non-combustibles | Outdoor: combustibles | Outdoor: non-combustibles |
|---|---|---|---|---|
| Top | 6 in. (152 mm) | 2 in. (51 mm) | 12 in. (305 mm) | 2 in. (51 mm) |
| Back | 0 in. | 0 in. | 0 in. | 0 in. |
| Front | 6 in. (152 mm) | 6 in. (152 mm) | Panel 24 in. (610 mm); exhaust 24 in. (610 mm) | Panel 0 in.; exhaust 24 in. (610 mm) |
| Sides | 2 in. (51 mm) | 1/2 in. (13 mm) | 6 in. (152 mm) | 1/8 in. (3.2 mm) |
| Ground / bottom | 12 in. (305 mm) | 12 in. (305 mm) | 12 in. (305 mm) | 2 in. (51 mm) |
| Vent | 0 in. | 0 in. | - | - |
Room temp must stay between 32 F (0 C) and 120 F (49 C).
Outdoor models need a weather-rated disconnect switch for the 120 V supply.
Models that show this code
7 models in Navien NPN
Other codes on the same units
- MAIN Remote asks for main/sub setting
- Master unit icon Master unit (cascade) indicator
- Preheat icon Recirculation schedule / preheat icon
- R&D information menu R&D information menu (Power off, key sequence)
- Remote LED Remote controller LED colour
- Remote lock icon Remote lock mode on
- SL.01 Cascade sub unit confirmed
- SL.xx Sub remote waiting for ID
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NPN-U/NPN-E Installation Manual, 2.4 The Front Panel, p.8. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.