Lennox · General
Ambient lockout Ambient lockout notice
What the display is showing
Outdoor temperature is outside the heat pump balance point settings. Below the low balance point the heat pump is locked out and only auxiliary heat runs. Above the high balance point auxiliary heat is blocked and only the heat pump runs. Default low is 25°F (-4.0°C) and default high is 50°F (10°C); the dealer can change both.
Applies to: Heat pump systems with auxiliary heat
Other codes on the same units
- Defrosting Outdoor unit defrost in progress
- Load shedding, wait time 45 min Utility load shedding with 45 minute wait
- Peak Monitoring until x:xx pm - x:xx pm Peak Monitoring energy savings period
- Service Urgent Service Urgent alert on Home screen
- System Under Test System Under Test after power interruption
- Will start soon Will start soon delay
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox S40 Smart Thermostat User Guide, p. 20. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.