Lennox · General

Ambient lockout Ambient lockout notice

Normal status S40 Smart Thermostat

What the display is showing

Outdoor temperature is outside the heat pump balance point settings. Below the low balance point the heat pump is locked out and only auxiliary heat runs. Above the high balance point auxiliary heat is blocked and only the heat pump runs. Default low is 25°F (-4.0°C) and default high is 50°F (10°C); the dealer can change both.

Applies to: Heat pump systems with auxiliary heat

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox S40 Smart Thermostat User Guide, p. 20. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.