FlowMax · Combi boiler

08 Frost protection active

Normal status FlowMax condensing combi (FLOWMAX-120)

What the display is showing

Code 08 means the frost protection function is running. Heating circuit: starts when the heating sensor reads 5 C, fires at minimum gas pressure with the 3-way valve in the winter position, and ends when the sensor reaches 30 C. Hot water storage models: starts when the storage sensor reads 4 C, heats the DHW circuit at minimum gas pressure with the valve in the summer position, and ends at 8 C. This is normal in cold conditions.

Applies to: FLOWMAX-120 condensing combi

Settings for these units

Other codes on the same units

  • 07 Flue test (chimney sweeper) function active
  • 22 Fan frequency readout (parameter 22)
  • 28 Legionella prevention cycle active
  • Curve number Compensation curve number display
  • OFF Switched off, frost protection still active
  • PL 0 Parameter menu entered

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: FLOWMAX-120 Instruction Manual, 6.11 Diagnostics - Function codes, p.68. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.