Daikin · Air conditioner

E27 Outdoor coil defrost sensor out of range

Medium severity Daikin FIT DC6VS/DC9VSA

What the control is telling you

Thermostat shows 27, outdoor board display shows E27. The defrost thermistor on the outdoor coil reads out of range.

Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Likely causes

  • Defrost thermistor bad or not plugged in right

Test and repair steps

  1. Kill power at the disconnect before opening the control box or touching wiring.
  2. Check the defrost thermistor plug and the sensor. Repair or replace.

Models that show this code

10 models in Daikin FIT DC6VS/DC9VSA

DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810

Other codes on the same units

  • E23 Discharge temperature sensor out of range
  • E24 High pressure switch open
  • E25 Outdoor air temperature sensor open or shorted
  • E26 Pressure sensor not responding
  • E28 Outdoor coil temperature sensor out of range
  • E29 Liquid temperature sensor out of range
  • E30 Control board may need replacing
  • E32 Outdoor control board overheating (critical)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.