Daikin · Air conditioner

E21 Repeated low discharge superheat faults

High severity Daikin FIT DC6VS/DC9VSA

What the control is telling you

Thermostat shows 21, outdoor board display shows E21. Discharge superheat keeps reading too low (liquid getting back to the compressor is the worry).

Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Likely causes

  • Thermistor bad or not plugged in right
  • Bad indoor or outdoor EEV, or its coil
  • Too much refrigerant
  • Bad pressure sensor
  • Bad control board

Test and repair steps

  1. Kill power at the disconnect before opening the control box or touching wiring.
  2. Check the thermistor plugs and readings.
  3. Check the indoor and outdoor EEV and their coils.
  4. Check the charge. Recover refrigerant if overcharged.
  5. Check the pressure sensor.
  6. Replace the control board last.

Models that show this code

10 models in Daikin FIT DC6VS/DC9VSA

DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810

Other codes on the same units

  • E17 Repeated compressor faults (critical)
  • E18 Control board may need replacing (outdoor fan drive)
  • E19 Repeated outdoor fan / board faults (critical)
  • E20 Outdoor EEV fault
  • E22 Repeated high discharge temperature faults
  • E23 Discharge temperature sensor out of range
  • E24 High pressure switch open
  • E25 Outdoor air temperature sensor open or shorted

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.43 (printed page). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.