Carrier air handler error codes

40 codes (37 faults, 3 normal display and menu codes).

CodeMeaningSeverity / type
EC0dODU malfunctionHigh
EC07ODU fan speed out of controlHigh
EC51ODU EEPROM parameter errorHigh
EC52ODU coil temp sensor errorMedium
EC53ODU ambient temp sensor errorMedium
EC54COMP. discharge temp sensor errorMedium
EC56IDU coil outlet temp sensor errorMedium
ECC1Other indoor unit refrigerant sensor detects leakage (multi-zone)Critical
EH00IDU EEPROM malfunctionHigh
EH0AIDU EEPROM parameter errorHigh
EH0EWater-level alarm malfunctionHigh
EH0bIDU main control and display board communication errorMedium
EH03IDU fan speed out of controlHigh
EH3AExternal fan DC bus voltage too low protectionHigh
EH3bExternal fan DC bus voltage too high faultHigh
EH60IDU room temp sensor (T1) errorMedium
EH61IDU coil temp sensor (T2) errorMedium
EH62/EH66Evaporator coil inlet temp sensor (T2B) open or shortMedium
EH65Evaporator coil inlet temp sensor (T2A) open or shortMedium
EHb3Communication malfunction between wired controller and IDUMedium
EHC1Refrigerant sensor detects leakageCritical
EHC2Sensor out of range and leakage detectedCritical
EHC3Refrigerant sensor working condition out of rangeHigh
EL0CSystem lacks refrigerantHigh
EL01IDU and ODU communication errorHigh
EL16Communication malfunction between adapter board and outdoor main boardMedium
FL09Mismatch between new and old platformsMedium
PC00ODU IPM module protectionCritical
PC0LLow ambient temperature protectionMedium
PC01ODU voltage protectionHigh
PC02Compressor top (or IPM) temperature protectionHigh
PC03Pressure protection (low or high pressure)High
PC04Inverter compressor drive errorCritical
----IDU mode conflictMedium
CPRemote switch off, unit blockedNormal status
DFDefrost mode indicationNormal status
EH 0EWater level switch overflowHigh
EHbACommunication error between IDU and external fan moduleMedium
FCForced cooling modeNormal status
FHCCRefrigerant sensor malfunctionHigh

Models covered

18K24K30K36K (XA3)36K (XB3)45MBAAQ18XB345MBAAQ24XB345MBAAQ30XB345MBAAQ36XA345MBAAQ36XB345MBAAQ48XA345MBAAQ60XA345MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX348K60KD5FLAAH36XAKD5FLAAH48XAKD5FLAAH60XAKD5FSAAD5FSAAH18XBKD5FSAAH24XBKD5FSAAH30XBKD5FSAAH36XBKD5FUAAD5FUAAH18XAKD5FUAAH24XAKD5FUAAH30XAKD5FUAAH36XAKD5FUAAH48XAKD5FUAAH60XAKD5FUHAH24AAKD5FUHAH24XAKD5FUHAH36AAKD5FUHAH36XAKD5FUHAH60AAKD5FUHAH60XAKD5FULAH24XAXD5FULAH24XBXD5FULAH36XAXD5FULAH36XBXD5FULAH36XCXD5FULAH60XDXD5FULAH60XMXEHKMD05KNEHKMD08KNEHKMD10KNEHKMD15KNEHKMD20KNEHKMD25KN

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.