Bosch · Tankless water heater

Solar mode Solar mode indicator

Normal status Bosch Greentherm T9800 SEBosch Greentherm T9900 SE

What the display is showing

The solar mode indicator on the display means the burner did not light because the incoming water is already warm: even at minimum firing the set temperature would be exceeded. This usually happens when inlet temperature is at or above the set point minus 1 F (0.5 C). It is not a fault.

Applies to: Greentherm T9800 SE 160/199 and T9900 SE 160/199 tankless water heaters

Models that show this code

6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE

Greentherm T9800 SE 160Greentherm T9800 SE 199Greentherm T9800 SEC 199Greentherm T9900 SE 160Greentherm T9900 SE 199Greentherm T9900 i 199

Other codes on the same units

  • HS HS about
  • OD OD operation data
  • Open Taps Open Taps message during auto adjust
  • PA PA water actuator (valve calibration)
  • PE PE appliance type (read-only data)
  • SA SA settings menu
  • Setpoint display Set temperature shown on touch display
  • UC UC auto adjust (gas and air)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Bosch Greentherm T9800 SE 160-199 installation 6720816815 (06.2023), 6.4.2 Solar Mode p.46; T9900 SE 160-199 installation 6 720 813 635 (2024-06) same section. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.