Bosch · Tankless water heater
Open Taps Open Taps message during auto adjust
What the display is showing
During the automatic gas and air adjustment (UC Auto Adjust) the display shows Open Taps when more water flow is needed. Open more hot water taps (a tub and two sinks are usually enough) and let the process continue. It starts about 5 minutes into the adjustment and a green check mark shows when it finishes.
Applies to: Greentherm T9800 SE 160/199 and T9900 SE 160/199 tankless water heaters
Models that show this code
6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greentherm T9800 SE 160-199 installation 6720816815 (06.2023), 8.11.1 Automatic Gas and Air adjustment p.60-61; T9900 SE 160-199 installation 6 720 813 635 (2024-06) same section. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.