Bosch · Tankless water heater
CA Water flow above 9.2 gpm
What the control is telling you
Measured water flow is higher than the unit can handle.
Applies to: Bosch Greentherm T9800 SE 160/199 and T9900 SE 160/199 / i 199 tankless water heaters
Likely causes
- Air in the water circuit
- No flow restrictor
- Water pressure over 150 psi
Test and repair steps
- Disconnect power and purge the hydraulic circuit of air.
- Install a flow restrictor.
- Check that the water pressure stays below 150 psi.
Models that show this code
6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE
Other codes on the same units
- AU AU technical settings (service mode)
- BB Fan calibration after missed ignitions
- BC Repeated fan calibration with similar values
- Burner symbol Burner status symbol - burner on
- CE Flue blockage during operation (siphon pressure)
- CF Flue blockage during operation (insufficient air)
- DH DH data history
- Display blank Display blank - appliance off
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greentherm T9800 SE 160/199 installation 6720816815 (06.2023), Table 24 Error code diagnostics, p.65-69; Bosch Greentherm T9900 SE 160/199 | i 199 installation 6 720 813 635 (2024-06), section 9.1 Error code diagnostics, p.68-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.