Allied · Furnace
LED on Normal operation
What the display is showing
Steady LED on the control means the board is powered and running normally.
Applies to: A95UH, A93UH, 95G1UH, 92G1UH (sizes 045-08 to 135-20)
Models that show this code
15 models in A95/A93/95G1/92G1UH, A95/95G1UH, A93/92G1UH
Other codes on the same units
- 3 flashes Pressure switch open with inducer on
- 4 flashes High limit switch open
- 5 flashes Rollout switch open
- 6 flashes Pressure switch cycle lockout
- 7 flashes Lockout - no ignition
- 8 flashes Lockout - too many flame dropouts
- 9 flashes Incorrect line voltage phasing
- LED off No power to control or control hardware fault
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Allied 506724-01 (Issue 1108) A95UH/A93UH/95G1UH/92G1UH Installation Instructions, Diagnostic Codes p.53. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.