AirQuest · Furnace

13 Limit circuit lockout

High severity

What the control is telling you

The limit circuit opened too many times; the control is in lockout.

Applies to: Carrier/ICP-family two-digit status codes — confirm with the code label on the unit

Likely causes

  • Dirty filter / restricted airflow
  • Closed supply registers
  • Blower not running or wrong speed tap
  • Undersized ductwork
  • Over-firing

Test and repair steps

  1. Replace or clean the air filter
  2. Confirm the blower runs and speed taps are correct for heat
  3. Check temperature rise against the rating plate
  4. Inspect ductwork and registers for restrictions
  5. Check manifold gas pressure

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Carrier/ICP status code label — verify per model. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.