Weil-McLain · Boiler parts
Weil-McLain Ultra Series 4: parts list
17 replacement parts with OEM part numbers for 20 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| 3 in vent bird screen Cut to size if needed. Sold separately. | 383-500-105 | All Ultra models using 2 in or 3 in vent/air termination | 1 | 2 in or 3 in termination |
| 4 in vent bird screen Cut to size if needed. Sold separately. | 383-500-110 | All Ultra models using 3 in or 4 in vent/air termination | 1 | 3 in or 4 in termination |
| Low voltage circuit fuse Low voltage circuit fuse on the U-Control | 257003 | Ultra 80, 105, 155, 230, 299, 399 | 1 | 3 A fast-blow |
| Line voltage circuit fuse Line voltage circuit fuse in the control pod | 326012P | Ultra 80, 105, 155, 230, 299, 399 | 1 | 12 A slow-blow |
| Maintenance kit (80 and 105) Keep on hand for annual maintenance in case replacement is needed | 383-500-605 | Ultra 80, Ultra 105 | 1 | |
| Maintenance kit (155/230/299/399) Keep on hand for annual maintenance in case replacement is needed | 383-500-620 | Ultra 155, Ultra 230, Ultra 299, Ultra 399 | 1 | |
| Natural to propane conversion kit, sea level (to 5,500 ft) Special order; in kit only | 383-501-020 | Ultra-80 | 1 | |
| Natural to propane conversion kit, sea level (to 5,500 ft) Supplied with boiler; see page 48 | 540-100-001 | Ultra-105 | 1 | |
| Natural to propane conversion kit, sea level (to 5,500 ft) Supplied with boiler; see page 49 | 383-500-115 | Ultra-155 | 1 | |
| Natural to propane conversion kit, sea level (to 5,500 ft) Supplied with boiler; see page 49 | 383-500-120 | Ultra-230 | 1 | |
| Natural to propane conversion kit, sea level (to 5,500 ft) Supplied with boiler; see page 49 | 540-202-832 | Ultra-299 | 1 | |
| Natural to propane conversion kit, high altitude (above 5,500 ft) Special order; see page 48 or kit | 383-500-644 | Ultra-80LP | 1 | |
| Natural to propane conversion kit, high altitude (above 5,500 ft) Special order; see page 48 or kit | 383-500-645 | Ultra-105 | 1 | |
| Natural to propane conversion kit, high altitude (above 5,500 ft) Special order; see page 49 or kit | 383-500-646 | Ultra-155 | 1 | |
| Natural to propane conversion kit, high altitude (above 5,500 ft) Special order; see page 49 or kit | 383-500-647 | Ultra-230 | 1 | |
| Natural to propane conversion kit, high altitude (above 5,500 ft) Special order; see page 49 or kit | 383-500-394 | Ultra-299 | 1 | |
| Propane to natural conversion kit Special order; in kit only | 383-501-021 | -80 | 1 |
Source: Ultra Series 4 boiler manual, p. 128 (pages 19, 115, 116, 128). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.