Viessmann Vitotronic 300-K MW1S: parts list

11 replacement parts with OEM part numbers for 1 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
Viessmann LON cable
Used for control unit to control unit or Vitocom connections.
7143 495Vitotronic 300-K MW1S17 m / 23 ft per segment
End of line resistor
Standard delivery with Vitotronic 300-K MW1S; one at each end of the line.
7143 497Vitotronic 300-K MW1S2
LON coupling
Allows up to 3 LON cables between two devices.
7143 496Vitotronic 300-K MW1S1
Mixing valve circuit extension kit
Extension kit for the mixing valve circuit.
7450 650Vitotronic 300-K MW1S1
Mixing valve motor
Run time from close to open 120 s. For 24 V actuators, see the actuator instructions.
7133 390Vitotronic 300-K MW1S1120 VAC~, 60 Hz, 4 W, 3 Nm
Mixing valve motor
Run time close to open 120 s. Rotation direction can be reversed by turning plug A 180°.
7133 390All 1 models1120 VAC, 60 Hz, 4 W, 3 Nm, IP 42
Mixing valve circuit extension kit
For mixing valve circuit extension.
7450 650All 1 models1
Vitotrol 200 remote control with integral room temperature sensor
Used with a mixing valve circuit for room temperature feedback. Mounts on a wall base.
7450 017All 1 models1
Vitotrol 300 remote control with integral room temperature sensor
Used with a mixing valve circuit for room temperature feedback. Mounts on a wall base.
7450 790 or 7179 060All 1 models1AAA alkaline batteries (MICRO LR03)
Room temperature sensor
Use when the remote Vitotrol cannot be mounted in a suitable location. Check resistance at terminals 9 and 13b.
7408 012All 1 models1IP 30
Input Module 0 to 10 V
Requires software version 7 or later on the Vitotronic 300-K MW1S
7134 561All 1 models10 to 10 V DC input, fuse F1 50 mA slow

Source: Viessmann Vitotronic 100 GC1 / Vitotronic 300-K MW1S installation and service instructions, p. 68 (pages 68, 128, 130, 132, 136, 137). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.