Viessmann Vitotronic 300 GW2: parts list
63 replacement parts with OEM part numbers for 8 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Front panel with heating circuit selector buttons Used to display and select the heating circuit. | 7818 623 | Vitotronic 300 GW2 | 1 | |
| Fuse box (contains fixed high limit, adjustable high limit, fuses, heating system switch and TEST button) Houses the fixed high limit, adjustable high limit, fuses, heating system switch and TEST button. | 7820 172 | Vitotronic 300 GW2 | 1 | |
| LON communication module (accessory) Inserted in the control unit. Interruption of communication is indicated. | 7172 173 | Vitotronic 300 GW2 | 1 | |
| LON terminal resistor Fit one on each of the first and last control units in a LON chain. | 7143 497 | Vitotronic 300 GW2 | 1 on first control unit and 1 on last control unit | |
| Boiler coding card for Vitorond 200 (coding 1020) Used with Vitotronic 300 on this boiler. | 7820 142 | Vitorond 200 | 1 | |
| Boiler coding card for Vitocrossal 300, Type CT3 (coding 1040) Used with Vitotronic 300 on this boiler. | 7820 144 | Vitocrossal 300 Type CT3 | 1 | |
| Boiler coding card for Vitocrossal 200, Type CM2 (coding 1041) Used with Vitotronic 300 on this boiler. | 7820 145 | Vitocrossal 200 Type CM2 | 1 | |
| TEST button (checks the fixed high limit) Used to check the fixed high limit. See description on page 65. | 7819 314 | Vitotronic 300 GW2 | 1 | |
| Fixed high limit (electromechanical, liquid expansion, with interlock) Cuts out and interlocks to limit boiler water temperature. Also interlocks if the capillary leaks or ambient is below -10 °C / 14 °F. | 7820 036 | Vitotronic 300 GW2 | 1 | Factory setting 110 °C / 230 °F |
| Adjustable high limit (electromechanical, liquid expansion) Limits maximum boiler water temperature, for example in emissions test mode. | 7817 531 | Vitotronic 300 GW2 | 1 | Factory setting 95 °C / 203 °F |
| Outdoor temperature sensor Permissible ambient -40 to +70 °C (-40 to 158 °F) during operation, storage and transport. | 7820 148 | Vitotronic 300 GW2 | 1 | IP 43 |
| Boiler temperature sensor Electrical connection shown on page 38. | 7450 632 | Vitotronic 300 GW2 | 1 | IP 32; 0 to +130 °C (32 to 266 °F) in operation |
| DHW tank temperature sensor Electrical connection shown on page 38. A second DHW tank sensor can be connected. | 7450 633 | Vitotronic 300 GW2 | 1 | IP 32; 0 to +90 °C (32 to 194 °F) in operation |
| Extension kit for heating circuit with mixing valve (supply temperature sensor, mixing valve motor, 4 m cable, plug for heating circuit pump) Accessory. Supply sensor is a contact sensor. | 7183 288 | Vitotronic 300 GW2 | 1 | 4 m / 13 ft connecting cable |
| Flue gas temperature sensor (VD2/VD2A/CT3 only) Accessory. Plugs into socket 15 on the boiler control. For CM2 flue gas temperature switch see page 48. | 7450 630 | VD2, VD2A, CT3 | 1 | IP 60; -20 to +600 °C (32 to 1112 °F) in operation |
| Flue gas temperature sensor Plugs into socket 15 on the boiler control. CM2 flue gas temperature switch is on page 48. | 7450 630 | VD2/VD2A/CT3 boilers | 1 | |
| Vitotrol 200 With integral room temperature sensor for room temperature feedback with a mixing valve circuit. Sets day temperature, heating program, economy and party mode. | 7133 378 | Vitotronic 300 GW2 | 1 | |
| Vitotrol 300 With integral room temperature sensor for room temperature feedback with a mixing valve circuit. Sets normal and reduced temperature, DHW temperature, heating program, holiday program, switching times, economy and party mode. | 7134 452 | Vitotronic 300 GW2 | 1 | |
| Room temperature sensor Used where the remote control cannot be placed in a suitable position to measure room temperature. | 7133 379 | Vitotronic 300 GW2 | 1 | Max. 35 m / 115 ft cable, 1.5 mm² copper |
| Hinges | Pos. 001 | Vitotronic 300 GW2 | 1 | |
| Optic link | Pos. 002 | Vitotronic 300 GW2 | 1 | |
| AHL Knob | Pos. 004 | Vitotronic 300 GW2 | 1 | |
| Fixed high limit cover | Pos. 005 | Vitotronic 300 GW2 | 1 | |
| Dial-stop 110°C/230°F | Pos. 006 | Vitotronic 300 GW2 | 1 | 110°C/230°F |
| Support arm | Pos. 008 | Vitotronic 300 GW2 | 1 | |
| Safety module (wired) | Pos. 011 | Vitotronic 300 GW2 | 1 | |
| Front housing (with Pos. 001) | Pos. 013 | Vitotronic 300 GW2 | 1 | |
| Circuit board enclosure | Pos. 014 | Vitotronic 300 GW2 | 1 | |
| Flip-down cover | Pos. 015 | Vitotronic 300 GW2 | 1 | |
| Rear housing | Pos. 016 | Vitotronic 300 GW2 | 1 | |
| Programming unit | Pos. 018 | Vitotronic 300 GW2 | 1 | |
| Flip-down cover | Pos. 019 | Vitotronic 300 GW2 | 1 | |
| Front cover for heating circuits | Pos. 020 | Vitotronic 300 GW2 | 1 | |
| Flat cable, 14-pole | Pos. 021 | Vitotronic 300 GW2 | 1 | 14-pole |
| Fuse holder cover | Pos. 024 | Vitotronic 300 GW2 | 1 | |
| Fuse holder | Pos. 025 | Vitotronic 300 GW2 | 1 | |
| Fixed high limit, 3510mm | Pos. 030 | Vitotronic 300 GW2 | 1 | 3510mm (as printed) |
| Adjustable high limit | Pos. 031 | Vitotronic 300 GW2 | 1 | |
| Switch, 1-pole (FHL test) | Pos. 037 | Vitotronic 300 GW2 | 1 | |
| Switch, 2-pole (power on/off) | Pos. 038 | Vitotronic 300 GW2 | 1 | |
| Sensor #1 for outdoor temperature | Pos. 040 | Vitotronic 300 GW2 | 1 | |
| Sensor #2 for supply | Pos. 068 | Vitotronic 300 GW2 | 1 | |
| Sensor #3 for boiler | Pos. 042 | Vitotronic 300 GW2 | 1 | |
| Sensor #5 for domestic hot water production | Pos. 043 | Vitotronic 300 GW2 | 1 | |
| Sensor (Immersion, NI500) | Pos. 067 | Vitotronic 300 GW2 | 1 | NI500 |
| LON module | Pos. 047 | Vitotronic 300 GW2 | 1 | |
| Circuit board (mixing valve expansion) | Pos. 048 | Vitotronic 300 GW2 | 1 | |
| Motherboard (control, low voltage) | Pos. 049 | Vitotronic 300 GW2 | 1 | |
| Circuit board (control software) | Pos. 050 | Vitotronic 300 GW2 | 1 | |
| Diagnostics module (Optolink) | Pos. 051 | Vitotronic 300 GW2 | 1 | |
| Motherboard (control, line voltage) | Pos. 052 | Vitotronic 300 GW2 | 1 | |
| Circuit board (120V power supply) | Pos. 054 | Vitotronic 300 GW2 | 1 | 120V |
| Motherboard (mixing valve expansion) | Pos. 055 | Vitotronic 300 GW2 | 1 | |
| Burner cable Nr. 41/90 | Pos. 065 | Vitotronic 300 GW2 | 1 | l=3470 |
| Harness for programming unit | Pos. 074 | Vitotronic 300 GW2 | 1 | |
| Fuse 6.3A / 250V (10 pack) | Pos. 092 | Vitotronic 300 GW2 | 10 pack | 6.3A / 250V |
| Accessory pack (plugs) | Pos. 060 | Vitotronic 300 GW2 | 1 | |
| Coding plug for Vitocrossal 200 | Pos. 061 | Vitotronic 300 GW2 | 1 | |
| Coding plug for Vitorond 200 | Pos. 062 | Vitotronic 300 GW2 | 1 | |
| Coding plug for Vitocrossal 300 | Pos. 063 | Vitotronic 300 GW2 | 1 | |
| Installation / Service Instructions | Pos. 080 | Vitotronic 300 GW2 | 1 | |
| Operating Instructions | Pos. 081 | Vitotronic 300 GW2 | 1 | |
| Parts List | Pos. 082 | Vitotronic 300 GW2 | 1 |
Source: Vitotronic 300 Installation and Service Instructions, p. 141 (pages 96, 97, 98, 99, 101, 104, 106, 108, 112, 141, 142). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.