Viessmann · Boiler · Vitotron 100 VLN2 series
VLN2-04 to VLN2-14.4 parts
39 replacement parts that fit the Viessmann VLN2-04 to VLN2-14.4, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Case set, back | 1001 | 1 | |
| Front cover | 1002 | 1 | |
| Power board, without connection | 2001 | 1 | |
| Control panel PSK.P7 | 2002 | 1 | |
| Board, ZIO 50 | 2003 | 1 | |
| Thermal safety, 60T-X25 | 2004 | 1 | |
| Contactor (Hartland) | 2005 | 1 | 40A 2P |
| Transformer (TEC) | 2006 | 1 | 24V |
| Fuse socket | 2007 | 1 | |
| Fuse, 6.3 x 32 mm | 2008 | 1 | 2A |
| Electrical connector, VC05-0013 | 2009 | 1 | |
| Holder, KU-2 gray | 2010 | 1 | |
| Thermal cut-out, 36T auto reset | 2011 | 1 | |
| Power board, with connection | 2012 | 1 | |
| Return temperature sensor NTC Not shown in illustration | 2013 | 1 | |
| Automatic air-vent valve | 3001 | 1 | |
| Gasket 1.5 x 8 x 14.8 | 3002 | 1 | |
| Gasket 1.5 x 11.7 x 18.2 | 3003 | 1 | |
| Gasket 2 x 20 x 30 | 3004 | 1 | |
| Expansion vessel 6 L, G1/2 | 3005 | 1 | 6 L, G1/2 |
| Gasket 1.5 x 16 x 24 | 3006 | 1 | |
| Pressure transducer | 3007 | 1 | |
| Differential pressure valve, 3/4 | 3008 | 1 | 3/4 |
| O-ring seal gasket, 70NBR | 3009 | 1 | 70NBR |
| Magnetic filter, 3/4 Clean at least annually | 3010 | 1 | 3/4 |
| Flow temperature sensor, DN15 | 3011 | 1 | DN15 |
| Heating box, 240V | 3012 | 1 | 240V |
| Return connection pipe | 3013 | 1 | |
| Pump connection pipe, internal | 3014 | 1 | |
| Flow connection I | 3015 | 1 | |
| Flow connection II | 3016 | 1 | |
| Nipple, 3/4 | 3017 | 1 | 3/4 |
| Nut, 1/2 | 3018 | 1 | 1/2 |
| Nut, G3/4 | 3019 | 1 | G3/4 |
| Connection pipe | 3020 | 1 | |
| Bushing | 3021 | 1 | |
| Circulating pump (Wilo) Star S21U-15 | 3022 | 1 | Star S21U-15 |
| O-ring 14 x 2 | 3023 | 1 | 14 x 2 |
| Safety valve with connection pipe | 3024 | 1 |
Same series
The Vitotron 100 VLN2 parts list shows every part for all 6 models side by side. Other models: VLN2 04, VLN2 06, VLN2 08, VLN2 12, VLN2 14.4.
Source: Vitotron 100 installation and service instructions (pages 21, 22, 23). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.